Chamberlain Group Inc The 6761 Manual De Usuario
23
BIPART DELAY
TIMER-TO-CLOSE (TTC)
LEARN BUTTON
DIAGNOSTIC DISPLAY
CONTROL BOARD OVERVIEW
The diagnostic display will show the operator type, firmware version, and codes. The operator type will display as “SL” followed by a “30”
which indicates the operator type as SL3000U. The firmware version will show after the operator type, example “1.2”. For more information
about the codes refer to the Troubleshooting section.
which indicates the operator type as SL3000U. The firmware version will show after the operator type, example “1.2”. For more information
about the codes refer to the Troubleshooting section.
HANDING BUTTONS
The TTC is factory set to OFF (0). Rotate the TIMER-TO-CLOSE dial to the desired setting (0 to 180 seconds). Any radio command, single
button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from
the open controls, loops, close edges, and close photoelectric sensors.
button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from
the open controls, loops, close edges, and close photoelectric sensors.
0 seconds (OFF)
The gate will remain open until the operator receives another command from a control.
1-180 seconds
(ON)
The gate will automatically close after the specified time period.
Used in dual gate applications where a maglock, solenoid lock, or decorative overlay would require one gate to close before the other.
The BIPART DELAY is also used in applications where one gate travels a longer distance than the other.
The BIPART DELAY is also used in applications where one gate travels a longer distance than the other.
ON
The operator with the BIPART DELAY dial ON will delay from the close limit when opening and be the first to close from
the open limit.
the open limit.
OFF
No affect.
BIPART
DELAY
2
4
6
8
The handing buttons are used to determine which direction the gate will open and they are also used to set the limits
(refer to the Adjustment section).
(refer to the Adjustment section).
OPEN RIGHT
If the operator is installed on the right side of the drive when looking out of the property, a swing gate
will swing to the right (turn counter clockwise) when opening and a slide gate will slide to the right when
opening.
will swing to the right (turn counter clockwise) when opening and a slide gate will slide to the right when
opening.
OPEN LEFT
If the operator is mounted on the left side of the drive when looking out of the property, a swing gate will swing to the left (turn
clockwise) when opening and a slide gate will slide to the left when opening.
clockwise) when opening and a slide gate will slide to the left when opening.
NOTE: For gates installed on the outside of the property, the setting will be opposite. Determine the direction by looking towards the property from the
outside.
outside.
HANDING
OPEN
LEFT
LEFT
OPEN
RIGHT
The LEARN button is used for programming (refer to Programming).