7.
Slowly open the valve and run enough water to
dissipate entrained air and flush the line.
8.
Check to make sure the meter is indicating flow.
9.
Check the meter for leaks.
2.3 Complete Installation
After the meter has been installed:
After the meter has been installed:
1.
Reset the transmitter. See “Send Reset Message” on
page 2 for instructions.
2.
Write down the odometer’s initial meter count for entry
into the TapWatch 2 software.
3.
Put the meter in rapid transmit mode. “Set Modes” on
page 2 for instructions.
3 Operation/Maintenance
3.1 Remove the Power Pack
If it is necessary to remove the power pack:
If it is necessary to remove the power pack:
1.
Lift the outside edge of the battery pack enclosure away
and up from the register to remove it.
2.
Use a flat blade screwdriver to evenly lift the battery
pack away from the register at the points marked
L
IFT
H
ERE
.
Caution:
Remove the power pack carefully. If the pins are
not kept perpendicular with the register during removal,
they may break. Never remove the power pack by rocking it
away from the register.
they may break. Never remove the power pack by rocking it
away from the register.
Figure 4
Remove the Battery Pack
3.2 Rotate the Register
If the odometer is difficult to read, the register can be
rotated.
If the odometer is difficult to read, the register can be
rotated.
Caution:
The register should only be rotated if absolutely
necessary. To rotate the register, you will need to purchase
a new security pin from Inovonics Wireless. The security
pin used in EN1550 is meant for one use only.
a new security pin from Inovonics Wireless. The security
pin used in EN1550 is meant for one use only.
1.
Use a punch to drive the security pin into the register
(Fig. 1).
2.
Turn the register 45 degress and lift it off of the meter.
3.
Remove the broken security pin from the bottom of the
register.
4.
Replace the register in the desired position.
5.
Use your thumb to insert a new security pin.
Note:
If you will need to rotate the register again, ensure
there’s appropriate clearance to remove the security pin in
the new position.
the new position.
3.3 How to Read the Meter
Figure 5
EN1550 Components
Flow indicator
The flow indicator spins when water is
flowing through the meter.
Odometer
The odometer displays the number of gallons
used, to the nearest 10 gallons.
Sweep hand
The sweep hand indicates the single digit
number of gallons that has passed through the meter. Each
full revolution indicates 10 gallons of consumption, and
will advance the first column on the odometer.
The meter in Figure 5 shows a consumption of 14.6
gallons. The odomoter indicates that 10 gallons have been
used, and the sweep hand adds 4.6 gallons to that
number.
full revolution indicates 10 gallons of consumption, and
will advance the first column on the odometer.
The meter in Figure 5 shows a consumption of 14.6
gallons. The odomoter indicates that 10 gallons have been
used, and the sweep hand adds 4.6 gallons to that
number.
3.4 Send Reset Message
When the EN1550 is reset, the count is zeroed and an RF
reset message is sent. The RF reset message is used for
registration into TapWatch software. To reset the EN1550:
When the EN1550 is reset, the count is zeroed and an RF
reset message is sent. The RF reset message is used for
registration into TapWatch software. To reset the EN1550:
1.
Push an unfolded paper clip through the guide hole to
press and hold the Operation
button for five seconds
(Figure 2).
3.5 Set Modes
In normal mode, the EN1550 transmits the flow count
approximately once per hour, or upon every 100 gallons of
water, whichever occurs first. When in rapid transmit
mode, the EN1550 transmits the flow count approximately
once per minute. Rapid transmit mode is used during
installation, to help ensure all your programmed end-
devices are functioning correctly.
In normal mode, the EN1550 transmits the flow count
approximately once per hour, or upon every 100 gallons of
water, whichever occurs first. When in rapid transmit
mode, the EN1550 transmits the flow count approximately
once per minute. Rapid transmit mode is used during
installation, to help ensure all your programmed end-
devices are functioning correctly.
A.
Flow indicator
B.
Odometer
C.
Sweep hand
B
A
C