Using the Charge Rack 
5-3 
DIAD 6 Charge Rack Manual 
 
 
 
 
 
Charging the Main Battery 
The rack provides power to the DIAD 6 terminals and 
allows the charging of the main batteries in the termi- 
nal. The intelligent battery charging system incorpo- 
rated into all DIAD 6 terminals prevents 
overcharging, which means that DIAD 6 terminals 
may be stored in the rack indefinitely without damage 
to the terminals, battery packs, or the rack. 
The rack supports a reduced power output to each ter- 
minal to allow simultaneous charging of all 30 units 
across the full temperature specification. The termi- 
nal will automatically reduce its power consumption 
in the rack by turning off its display and backlight. To 
communicate with the terminal, use the WLAN radio 
for the Charge Rack. The application software should 
turn off all other radios and features. If not, the oper- 
ating temperature range may be reduced and/or the 
power supply overloaded, which may result in an 
extended charge time or no charging. 
 
To Power a Terminal and Charge its Main Battery 
1.  Install the main battery pack in the terminal. 
2.  Slide the DIAD 6 terminal into one of the thirty terminal wells. The terminal screen turns off 
immediately when docked to conserve power.  Charging begins immediately if required by the 
DIAD 6 terminal. 
 
Charging Status Through Notification LEDs 
The terminal will indicate the charging status through the notification LEDs at the top of the ter- 
minal.  The LEDs operate as follows: 
 
Solid Orange 
Indicates that the terminal is docked in the rack and the battery is being 
charged. 
Solid Green 
Indicates that the terminal is fully charged. 
Solid Red 
Indicates that the terminal is docked in the rack and receiving power, 
but the battery appears to be worn out or defective. 
Blinking Orange 
Indicates that the terminal is docked and receiving power but is not 
charging because the battery is too hot or too cold. 
Off 
Indicates that the terminal is not docked in the rack, the terminal is 
defective, the rack is defective, or the rack is not receiving power.