The Universal Configuration Module
Page 46
Senstar LM100 Product Guide
Segment Settings and Zone assignments
Segment
The Segment field identifies the currently selected Segment
The selected Segment is divided into 2 equal Segment and the 
Segment
 number increments when you select the Split button;
The currently selected Segment merges with the previous Segment 
and the Segment number decrements when you select the Delete 
button; The LM100 system supports up to 50 segments
Zone
Specify the Zone to which the selected Segment is assigned; The 
LM100 system supports up to 50 zones 
Relay 
(Local Control mode)
Specify the Relay which will activate in response to an alarm 
condition in the selected Segment
Sequence button
The Sequence button is used to setup and define the physical 
locations of the installed luminaires
Profile button
The Sensitivity Profile records the detection signal response 
magnitude for each luminaire based on a similar disturbance along 
the full length of the protected fence
Split button
Select the Split button to divide the currently selected Segment into 
two equal segments
Delete button
Select the Delete button to merge the currently selected Segment 
with the preceding segment
Schedule tab
Setup automatic lighting controls for the defined luminaire zones
SD Card tab
Select the type of data that will be saved to an SD card on the 
LM100 gateway (troubleshooting feature)
Aux Cfig tab (setup the method of control and the I/O response)
Aux Control
Select Local to have the I/O controlled by the gateway; 
Select Remote to have the I/O controlled by the host security 
management system
Aux Option Card
Select Input if the processor includes an optional input card; 
Select Output if the processor includes an optional output card
Aux type
Specify each of the ten I/O ports as either an Input or Output
Input Configuration
Setup the gateway’s inputs and the optional input card’s 4 inputs
Output Configuration
Setup the gateway’s relay outputs and the optional output card’s 4 
outputs
Network Cfig tab
Setup the Silver Network communication parameters
GSM Cfig tab
Setup the parameters for the Senstar Wireless Gate Sensor
Remote Cfig tab
Specify outputs that will activate in response to alarm and 
supervision conditions for Senstar LM100s that are reporting alarms 
and supervision conditions through an UltraLink I/O system 
operating in Network Manager mode 
Configuration parameter
Descriptions