T245 Control System Manual
21
Proportional
Output
Set-Up Panel
Indicator
Function
O11 (S20)
Flashing 6+
(not used)
O12 (S20)
Flashing 6-
(not used)
O13 (S20)
Solid 1
(not used)
O14 (S20)
Solid 2
(not used)
O15 (S20)
Solid 3
(not used)
O16 (S20)
Solid 4
(not used)
Built-in to the R1300+ is a Set-Up Panel (see Figure 7) consisting of three
columns of indicator lights, seven push buttons, and a socket for a plug-in “key”.  As
shown in the diagram below, there are five configurable parameters (centre column of
lights) for each proportional (pulse-width modulation, PWM) output: Threshold,
Start PWM, Max PWM, Ramp Up, and Ramp Down.
The Set-Up Panel has “Output” lights 1+ to 6- which correspond directly to the
proportional outputs of the R1300+.  For adjustment of the proportional outputs of the
S20, the Output lights are re-used as per the “Set-Up Panel Indicator” column in the
above table.
The 12 R1300+ proportional outputs are indicated by the lights in the “Output”
column as follows:  When the “1_” and “+” lights are solidly on, the 1+ parameter is
being output is being adjusted.  The “1_” and “-” lights indicate 1-, and so on.  The table
above lists these as “Solid 1+” through “Solid 6-“.
The first 12 S20 proportional outputs (O1 through O12) are indicated by flashing
“1+” through flashing “6-”.  The table above lists these as “Flashing 1+” through
“Flashing 6-”.
The last 4 outputs (O13 through O16) of the S20 are indicated by the “1_” through
“4_” lights solidly on with both the “+” and “-” lights off.  The table above lists these as
“Solid 1” through “Solid 4”.