3. Considerations for Electrowelding
The electronics in the Digger Derrick Control System can be damaged by the high
currents and voltages employed in electrowelding.  If electrowelding must be performed
after the Control System has been installed, observe the following precautions to reduce
the risk of damage:
  Do not connect the ground clip to a point on the chassis close to the
enclosures.
  Disconnect the harnesses to the enclosures and sensors at the M.S. connectors.
Also disconnect the battery (PTO switch) and ground connections going into
the enclosures.
  Do not strike an arc close to the enclosures and sensors, or wiring leading into
the enclosures and sensors.
  Do not weld to the sensors.