Applied Concepts Inc ACMI007 Manual De Usuario

Descargar
Página de 72
Applied Concepts                                            011-0131-00 rev 2 
Page 30 
 
Setting ID 
S
ta
ti
o
n
a
ry
 
2
3
2
 &
 4
8
5
 
S
p
e
e
d
o
m
e
te
2
3
2
 &
 4
8
5
 
T
ra
ff
ic
 
2
3
2
 
Available Values 
Dec 
Hex 
Setting Description 
Appendix C Ref 
Default Setting 
 
85 
0x55 
Target Strength Sensitivity 
3 – Target Recognition 
32 
-- 
-- 
1 (min) – 32 (max) 
87 
0x57 
Sensitivity Hysteresis 
3 – Target Recognition
 
-- 
-- 
0 – 3 
88 
0x58 
Holdover Delay 
5 – Speed Presentation 
45 
45 
45 
Stationary and Traffic: 1 – 222 (~10 
sec) 
Speedometer: fixed at 45 (~2 sec) 
90 
0x5A  Format D Polled Modes 
2 – Serial Port Configuration 
232 
only 
-- 
-- 
0 = Polled Mode Disabled 
1 = Polled Mode Enabled 
Active for Serial Formats D0-D4 only 
91 
0x5B 
Format D Direction 
Character Enable 
2 – Serial Port Configuration
 
-- 
-- 
0 = Direction Character Disabled 
1 = Direction Character Enabled 
Enable Direction byte, Formats D0-
D3 only 
92 
0x5C  Format D Zero Report 
2 – Serial Port Configuration
 
232 
only 
-- 
-- 
0 = Disabled 
1 = Enabled 
Active only if setting 93 is enabled. 
With no target, sends zero every two 
seconds. 
93 
0x5D 
Format D Update on 
Change Only 
2 – Serial Port Configuration
 
232 
only 
-- 
-- 
0 = Disabled 
1 = Enabled 
Enables speed reporting only when 
the speed changes. 
Active for Serial Formats D0-D4 only 
98 
0x62 
Zeros After Target Loss 
2 – Serial Port Configuration
 
232 
only 
-- 
-- 
0 = No Zeros 
1 = One Zero 
2 = Stream Zeros 
99 
0x63 
Keep TX On with Target 
9 – TX Power Save 
-- 
-- 
0 = Disabled 
1 = Enabled 
If enabled, the TX On Time (64) is 
extended as long as a target is 
present. 
100 
0x64 
Max TX On Time 
9 – TX Power Save
 
-- 
-- 
0-60000 ms 
If Keep TX On with Target (99) is 
enabled, this setting forces the 
transmitter off after the set time even 
if a target is present.  When set to 0, 
Max TX time is infinite – the 
transmitter is never forced off as 
long as a target is present. 
116 
0x74 
Speed Sensor Address 
11 - System
 
2 – 254 (0x02 – 0xFE) 
Only for Stationary 485 model