Digigram PCX924HR Manual De Usuario
D i g i g r a m
10
How to check the installation
Once the driver and the cards are installed according to the procedure
described in this manual, you can verify that the card is properly installed and
works fine as follows:
described in this manual, you can verify that the card is properly installed and
works fine as follows:
• Menu <Start> <Settings> <Control panel>, <Sound and
Multimedia>, tab “Audio”, Default device (Playback device,
Recording device). The card’s channels can be selected. The card can
be used with any DirectSound application (see pages hereafter).
Recording device). The card’s channels can be selected. The card can
be used with any DirectSound application (see pages hereafter).
• The card is also visible via the np interface: Go to <Start>
<Programs> <Digigram> and select <Digigram Control Center>.
• In the “Digigram drivers” window, select the ‘General Information’
tab.
In the “Modules Information” window, you can see the HR
Runtime modules that have been installed, and their versions.
In the “Modules Information” window, you can see the HR
Runtime modules that have been installed, and their versions.
• In the “Digigram drivers” window, select the ‘Diagnostics’ tab.
You should see here the icons of the cards you have installed.
If the card you have installed is listed:
• Right click on the icon of the card.
• Select ‘Diagnostics’, and Play Sine. This plays in loop a sine
signal on the outputs of the card. You can also select Play file to
play in loop a file of your choice (PCM only).
If the playback is correct, the card is correctly installed and
works.
play in loop a file of your choice (PCM only).
If the playback is correct, the card is correctly installed and
works.
• To stop the playback, right click on the card icon, and select Stop
Activities.
The card is also visible via the DHS control panel (cf. dedicated
chapter next page).
If the card is not displayed:
• Make sure that during the HR runtime installation the “Driver
for the HR boards” has been selected in the “Select
components” window.
components” window.
• make sure that the card is correctly inserted in the PCI slot, and
screwed on the PC chassis.
• if necessary, uninstall HR runtime package as described in this
manual, and re-install it.