Audiotel International Limited 2-400-0001 Manual De Usuario
18
AUDIOTEL INTERNATIONAL MN400872 Issue 1 (08/04)
D
ETECT
IV User Manual
AUDIOTEL INTERNATIONAL MN400872 Issue 1 (08/04)
19
Broadband Burst IDENTIFY screen
The Broadband Burst Identify screen is very similar to the Broadband CW Identify screen, and also
shows an oscilloscope type of display of received broadband burst signal strength against time.
shows an oscilloscope type of display of received broadband burst signal strength against time.
The time scale can be changed using the Zoom In and Zoom Out on-screen buttons.
This increases or decreases the rate at which the display scrolls.
The audio output in this mode is broadband AM.
Alarm thresholds remain active in this mode and can be adjusted using the up and
Down controls.
When the alarm threshold is exceeded the appropriate alarm icon is displayed in the top right hand
corner of the display and an entry is made in the EVENT LOG.
corner of the display and an entry is made in the EVENT LOG.
In addition this mode also compares the received signals against a library of known signal
signatures. If the signal is recognised the signal type (e.g.: GSM) is also displayed in the top left
hand side of the screen.