SMC Networks D3USG Manual De Usuario

Descargar
Página de 69
ANSI C63.17-2006 
Methods of Measurement of the Electromagnetic and Operational Compatibility of UPCS Devices 
9.10
9.11
9.12
9.13
9.14
 General and special conditions 
If an alternate test method was used, the test report shall identify and describe that method, provide 
justification for its use, and describe how the results obtained through its use correlate with the methods 
specified by the standard to which the EUT was tested. Instrumentation, instrument attenuator and 
bandwidth settings, detector function, EUT arrangement, and all other pertinent details of the test shall be 
provided so that the alternate test method can be replicated. When automatic scan techniques were used, an 
explanation of how the highest emission relative to the limit from the EUT was determined and the scan 
rate used to obtain recorded emissions is to be included in the test report. The actual operating and 
environmental conditions (e.g., voltage, powerline frequency, temperature, relative humidity, etc.) shall be 
listed in the report. 
 Summary of results 
The test report summary section shall indicate whether the EUT passes or fails, and give margins (where 
applicable) with respect to the limits to which it was tested. If the equipment passes only with specific 
modifications or special attributes (such as shielded cables), this information shall be included in the 
summary results. 
 Required signatures 
The test report shall contain the signature of the representative of the organization performing the tests. In 
addition, the test report shall identify the staff responsible for the proper execution of the test, and the name 
and address of the party requesting the tests. If changes are made during the period of test to bring the EUT 
into compliance, the test report shall so indicate. In addition, the report submitted to the procuring 
organization or regulatory agency shall include a signed statement by the manufacturer or developer 
agreeing to the changes and their incorporation into production. 
 Test report appendixes 
The test report shall contain, if required, photographs or detailed sketches of the EUT configuration, 
showing sufficient information to allow the EUT to be reconfigured in a manner that would allow the 
original test to be replicated with a high likelihood that the test results would be in agreement with the 
results of the original test within acceptable tolerances. 
 Test report disposition 
The test report shall be maintained by the testing organization for a period of at least three years following 
the date of the test. The manufacturer may be required by a regulatory agency to maintain a copy of the 
report for a longer period of time. 
41 
Copyright © 2007 IEEE. All rights reserved. 
Licensed to Sid Sanders. ANSI order X_30788. Downloaded 11/19/2007 2:45 PM. Single user license only. Copying and networking prohibited.