3a: Setting up the Echo Remote:
•
Will the Echo Remote be used with a Gate Controller Unit (GCU) or a Dual Frequency Gate
Controller Unit (DFGCU) as the gate activator? NOTE: If activating an Echo remote directly
to a GCU/DFGCU, there can be NO other Primary Gate Access Unit in the network.
Controller Unit (DFGCU) as the gate activator? NOTE: If activating an Echo remote directly
to a GCU/DFGCU, there can be NO other Primary Gate Access Unit in the network.
No: Go to Step 4.
Yes: Press the Learn button on the GCU/DFGCU once, until the LED lights up solid, and
Yes: Press the Learn button on the GCU/DFGCU once, until the LED lights up solid, and
release.
-
Within 5 seconds, on the Echo Remote press the large button, button 2 and button 4 at the
same time, for 1 second, until the LED lights up, and release.
same time, for 1 second, until the LED lights up, and release.
-
The LED on both units will double blink, 3 times, and the remote will beep, indicating
success.
success.
-
Proceed to Step 3b.
3b: Setting up the Echo Remote:
• Will you be using more than 1 Echo Remote?
No: Go to Step 3c.
Yes: NOTE: Before starting this step, please make sure you disconnect power to the
GCU/DFGCU. On the additional Echo Remote, press the large button, button 2 and
button 4 at the same time, for 1 second, until the LED lights up, and release.
button 4 at the same time, for 1 second, until the LED lights up, and release.
-
Within 5 seconds, on the main Echo Remote (the one activated to the GCU/DFGCU),
press the large button only, 1 time.
press the large button only, 1 time.
-
The LED on the additional unit will double blink, 3 times, and the LED on the main unit
will blink twice, indicating success.
will blink twice, indicating success.
-
For any additional remotes please repeat Step 3b for each unit that will be used.
-
Proceed to Step 3c.
3c: Setting up the Echo Remote:
• Will you be using more than 1 GCU/DFGCU with your Echo Remotes?
No: Go to Step 6.
Yes: NOTE: This will allow up to (4) gate controllers to be activated independently by
each of the 4 buttons based on their controller ID# (1-4)..
Setting the Gate Controller ID (1-4)
If you are using more then one Gate Controller, the additional units must have their ID set.
The Gate Controller ID is set by changing dipswitches #1&2 in the Gate Control Unit (see
picture below)
picture below)
2
GCU ID
SW1
SW2
1
off off
2
on off
3
off on
4
on on
Example:
The dipswitches for Gate
Controller #2 would look like this:
Proceed to Step 6.