Lutron Electronics Company Inc 0040 Manual De Usuario

Descargar
Página de 28
RadioRA
®
 Setup Guide for the Entry Master Control
24
Section 5 - T
roubleshooting
Troubleshooting Guide
Proper operation of the RadioRA
®
 Wireless Central Home Lighting Control System is based upon a complex
series of radio frequency (RF) communications between system components. As such, it is highly dependent
upon proper system installation and programming of controls.
If you experience difficulties programming or operating your RadioRA
®
 system, please refer to this guide.
Many symptoms of common system activation or programming errors are contained in this Troubleshooting
Guide. If you are having a problem with your system not described here, or if you have any questions, call
the 
Lutron Technical Support Center at 1-800-523-9466.
Symptom
Possible Cause
Remedy
Discontinue activating your RadioRA
®
system until activation of the neighboring
system is complete.
Move a system Repeater closer to the
Multi-Function Entry Master Control in
question, or you may have to add another
Repeater.
Place system in ACTIVATE CONTROLS
mode.
Check that breaker is on and not tripped.
Verify that the plug in power supply is
working.
Reprogram the Multi-Function Entry
Master Control.
Verify whether the Multi-Function Entry
Master Control is in range of a Repeater
by placing the system in BEEP mode.
(Refer to the Troubleshooting Section in
the RadioRA
®
 Setup Guide P/N 044-001.)
Entry Master Control must learn Visor
Control Transmitter.
Replace batteries in Visor Control
Transmitter with new ones (CR2032).
I
II
III
IV
V
ACTIVATE CONTROLS LED on
MAIN or AUXILIARY Repeater
turns ON and then back OFF
when attempting to go into
ACTIVATE CONTROLS mode.
After activating a Multi-Function
Entry Master Control, the Multi-
Function Entry Master Control
LEDs flutter for approximately 5
seconds then go out.
The Multi-Function Entry Master
Control appears not to be
working at all and the LEDs are
OFF.
The Multi-Function Entry Master
Control appears not to be
working at all and the LEDs are
glowing dimly.
The Visor Control Transmitter is
not communicating with the
Multi-Function Entry Master
Control.
Your system has encountered a
neighboring system within RF
communication range also in
ACTIVATE CONTROLS mode.
Multi-Function Entry Master
Control is out of RF communica-
tion range of nearest system
Repeater.
System not in ACTIVATE
CONTROLS mode.
No power available to the Multi-
Function Entry Master Control.
Faulty power supply.
The Multi-Function Entry Master
Control was not programmed
properly.
The Multi-Function Entry Master
Control may be out of RF
communication range of the
nearest Repeater.
Entry Master Control failed to
learn Visor Control Transmitter.
Batteries weak or dead.