2.2 Register Set
The reader has several system registers used for customization purposes. These registers are
stored in its non-volatile EEPROM. The reader accepts changes to these settings only during the
start-up phase. [See Write EEPROM, page 68]
stored in its non-volatile EEPROM. The reader accepts changes to these settings only during the
start-up phase. [See Write EEPROM, page 68]
Some of the system registers are organized such that each of the 8 bits is an on-off selection for a
feature. These are referred to as Flags. [See Set Configuration Flags, page 54]
feature. These are referred to as Flags. [See Set Configuration Flags, page 54]
Clearing all RFU bits is recommended in order to guarantee compatibility with future releases.
In addition, direct changes to some of these system registers may be made at any time, with
immediate effect, but these changes are NOT stored in EEPROM and thus are lost when the reader
powers down. [See Set Configuration Flags, page 54 and Set Configuration Register page 56]
These ‘on-the-fly’ changes are mapped onto the EEPROM ‘registers’ or memory locations and do
not necessarily carry the same ‘register’ values.
immediate effect, but these changes are NOT stored in EEPROM and thus are lost when the reader
powers down. [See Set Configuration Flags, page 54 and Set Configuration Register page 56]
These ‘on-the-fly’ changes are mapped onto the EEPROM ‘registers’ or memory locations and do
not necessarily carry the same ‘register’ values.
The reader can store up to 32 authentication keys internally to login standard MIFARE cards. An
additional 32 keys can be stored for DESFire authentication. All keys are read only and cannot be
accessed through the interface lines.
additional 32 keys can be stored for DESFire authentication. All keys are read only and cannot be
accessed through the interface lines.
2.2.1 EEPROM Memory Organization
Register
Description
00h … 04h
Unique device ID; read only
05h … 09h
Administrative data; read only
0Ah Station
ID
0Bh
Protocol configuration 1
0Ch Baud
rate
0Dh
Command Guard Time
0Eh Operation
Mode
0Fh
Single shot time-out value
10h
TMR low *
11h
TMR high *
12h
Type B framing *
13h
Protocol configuration 2
14h Reset
Off
Time
15h
Reset Recovery Time
16h
Application Family Identifier
17h
ISO 14443A Selection Time-out
18h
ISO 14443B Selection Time-out
19h
SR176 Selection Time-out
1Ah
ISO 15693 Selection Time-out
1Bh
Protocol configuration 3
1Ch Page
Start
1Dh
Modulation conductance 0 (Type B and SR176. Also ISO15693 if set to 10%
modulation)
modulation)
1Eh Threshold
August 2010
Page 23 of 144
© 2005-2010 HID Global Corporation. All rights reserved.