Troubleshooting the HandHeld Reader
The LED on the HandHeld Reader is not lit.
1.  Check to make sure the RJ45 connector is securely seated into the connection location on
the Symbol HandHeld Computer.
2.  Make sure the HandHeld Computer is turned on. Make sure the red LED is blinking. If the
HandHeld Reader connection is secure and the LED is not blinking, contact Technical
Support.
When I present a tag, the LED flashes red at about once per 3 seconds
1.  Be sure the HandHeld Reader is oriented in the correct position to read the tag, refer to figure
2.
2.  Confirm that the HandHeld Reader is with ½” to 6” (0”-2” if PC in box) from the tag for best
read/write performance.
3.  Be sure that a command/process was selected from the menu on the HandHeld Computer.
4.  Be sure the system being read has the AssetID™ subsystem installed.
When I present a tag, the LED flashes at rate greater than once per 3 seconds but does not
flash green
1.  Be sure the HandHeld Reader is oriented in the correct position.
2.  Be sure the AssetID subsystem of the system being read/written is operating normally.