SELECTING A FILLER OR REQUEST TO EXIT LABEL 
The filler piece replaces the antenna housing on the controller 
keypad when you use the high security installation.  If you do 
not plan to use the filler piece as a Request to Exit switch: 
1. Insert the filler piece into the opening on the 
controller keypad. 
2. Apply the blank label. 
 
FIGURE 
8: 
ATTACHING THE ANTENNA HOUSING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
If you plan to use the filler piece as a Request to Exit switch: 
1. Remove the two plastic side tabs on the filler piece. 
2. Insert the silicone rubber cushion over the two 
alignment pins on the switch activator. 
3. Apply the “Press to Exit” label to the filler piece. 
4. Insert the filler piece into the opening on the 
controller keypad. 
5. Refer to Figure 15 to make the wiring connections 
to the cable assembly if you are using a door contact. 
6. Set the internal Request to Exit button ON, using 
programming Command 30, option 7 (see Table 2).