Indoor Broadband Transmitter – ITX02-2000 
IM402513-10  Rev – 
Microwave Low Noise Amplifier 
A Low Noise Amplifier accomplishes the amplification with minimum distortion. 
DC Diagnostics Circuit 
Certain test points in the transmitter can be monitored externally at the Remote Monitor output 
multi-pin connector on the front panel.  These DC diagnostics are connected to the output 
connector through a signal conditioning circuit.  The signal conditioning circuit is a network of 
resistors that provides short circuit protection for the transmitter diagnostic sources.  The output 
connector is designed for use with diagnostic test boxes such as the Cable AML DTB - 1, the 
WRM-2, or the RM-2A.  The test points and corresponding connector pin connections are shown 
in the Transmitter Block Diagram. 
Power Supply 
The power supply for the MMDS Driver is +12 VDC.  
2.2  Power Amplifier Chains 
The power amplifier consists of four GaAs FET microwave power amplifier that amplifies the 
input signal to a maximum level consistent with the Carrier to Composite Triple Beat (C/CTB) 
specification.  The power amplifier is protected from failure due to overheating by an internal 
temperature sensor.  The sensor circuit automatically switches off the amplifier input power 
when the amplifier temperature exceeds 167
°
F (75
°
C).  The power amplifiers are arranged in a 
quadruple power configuration which results in an overall IP3 increase of 5 dB.  The gain of the 
amplifiers is 56 dB with an IP3 of 69.5 dBm.  The amplifiers have a TTL circuit, which enables 
the user to shut down the amplifiers for testing purposes.  +5VDC = “ON” 
2.3  Power Supply Assembly 
The transmitter has a 12 VDC redundant power supply system consisting of three current-
sharing modules with hot-plug replacement capability.  Each module has an 84 Amp capability.  
Only two modules in each mainframe are needed to run the transmitter.  A 24 VDC power 
supply powers the internal downconverter and also supplies voltage to a 5 VDC voltage 
regulator, which is used with the Transistor-Transistor-Logic (TTL) of the power amp.  A 
separate +12 VDC power supply is used for the Driver. 
2.4  Diagnostic Circuits1  
The ITX02-2000 transmitter has several connectors and switches. 
Connectors - there are "test point" and "monitor" output connectors on the front panel.  Their 
position in the circuitry is shown in Figure 3. 
                                                           
1See Data Manual for nominal values of diagnostic signals.