Hughes Network Systems 24HX-001 Manual De Usuario
1027145 – 0001 Revision E
Commissioning HTs 7–7
Hub installation
Use the LCD Status option to check the status of the CCM, SSIs,
and ODU, as explained in the following sections.
and ODU, as explained in the following sections.
Check the CCM status as follows:
1.
Press Enter on the CCM front panel.
The LCD shows:
Main Menu
Status
Status
2.
Press Enter, to go to (select) the Status menu:
Status
CCM
3.
Press Enter to show the CCM status:
CCM
OK
The possible status conditions for CCMs, SSIs, and the
ODU are:
ODU are:
OK
The component is operational.
Degraded
The component is not fully operational.
Failed
The component has failed.
Unknown
The CCM cannot communicate with the
component.
component.
Action for “Failed” or “Degraded”status
If the LCD shows
Failed
for any component, replace the
component.
If you see
Degraded
during installation, replace the
component. However, if you see
Degraded
while the
system is operation, under some circumstances you may not
need to replace the component (for example, if a failed port
is not needed).
need to replace the component (for example, if a failed port
is not needed).
7.3
Checking
component status
component status
Check CCM status