Hughes Network Systems 24HX-001 Manual De Usuario

Descargar
Página de 179
1027145 – 0001   Revision E
 9–6  Troubleshooting
Hub installation
Are SSIs
installed and
configured?
"HT Disabled" message is
normal if SSIs have not been
installed and configured.
Yes
No
hb113
After CCM has downloaded
its software, CCM LCD shows
"HT Disabled" message.
Problem:
Troubleshooting: "HT Disabled"
If Status screen shows
"Degraded" or
"Unknown" for any
component . . .
Check CCM,
SSIs, and ODU
via CCM LCD
Status menu.
If Status screen shows
"CCM Failed" or
"SSI
Failed" . . .
(number)
Refer to
section
If Status screen shows
"ODU Failed" . . .
Replace the
CCM or
indicated SSI.
1. Check IFL cable
for continuity.
2. Check IFL cable
connectors.
3. Replace ODU.
7.3.
IDU chassis fan doesn’t work. If the chassis is a dc powered unit,
make sure the polarity of the wires to the power supply is not
reversed.
If you find a faulty component, contact your contract administer to
arrange for repair or replacement.
9.2
Additional
troubleshooting
information
9.3
Repair or
replacement service