Hughes Network Systems 24HX-001 Manual De Usuario

Descargar
Página de 179
1027145 – 0001   Revision E
 10–10  Maintenance
Hub installation
If you need to replace the CCM, follow these steps:
If you need additional details concerning the instructions below,
see section 6.4 (page 6–26).
Removing the existing CCM
1.
Make sure the EMS operator has taken the HT out of
service.
2.
Remove power from the IDU chassis power supply.
3.
Loosen the thumbscrews at each end of the (existing) CCM.
4.
Using an ESD wrist strap connected to a chassis ground
terminal, slide the CCM out of its slot, as shown in 
figure 10-6.
CAUTION
Always wear a new or recently tested
electrostatic discharge (ESD) wrist strap
(figure 6-16) when handling circuit
modules. Failure to use a wrist strap may
result in damage to components.
Figure  10-6
Removing the CCM
hb118
TM
BROADBAND
ENTER
HUB CCM
5.
Place the CCM in ESD protective packaging.
Installing the replacement CCM
6.
Slide the replacement CCM into the CCM slot (slot 1).
7.
Tighten the thumbscrews at each end of the CCM.
8.
Apply power to the IDU chassis power supply.
9.
Use the CCM LCD to check the CCM status. (For details,
see section 7.3).
10.
Notify  the EMS operator that the HT is ready to resume
service.
10.5
Replacing the CCM