Hughes Network Systems 24HX-001 Manual De Usuario

Descargar
Página de 179
C.3
1027145 – 0001  Revision E
 C–6  Terminating IFL cables
Hub installation
8.
Flare the braid slightly and trim to 7/16 inch (11
millimeters), as shown in figure C-5.
Jacket
Braid
hb093
7/16 inch
(11 millimeters)
Figure  C-5
Braid, flared and trimmed
9.
Cut approximately 1/4 inch (6 millimeters) of the excess
braid so that all braids will be under the crimp ring when
the connector is completed.
The following steps explain how to attach the IFL (N) connector.
The same type of connector is used at both ends. The connector
includes a plastic guide pin to protect the dielectric during
installation, as shown in figure C-6.
Figure  C-6
IFL (N) connector (HNS
 9006284–0002)
Crimp
ring
Insulating
washer
Center
pin
Plastic
guide
pin
T0006020
Support
shoulder
Jam
nut
Connector body
Collar
Do not remove the plastic guide pin until instructed to do so
(step 4 on page C–8).
CAUTION
Do not install the center pin without the
plastic guide pin—doing so will damage
the dielectric material inside the connector
body.
Attaching the
connector