Notes:  
 
(1) The maximum continuous total DC outputs power shall not exceed 750W.   
(2) The maximum continuous load on +5V and +3.3V outputs shall not exceed 170W.   
(3) The maximum combined current for the +12V outputs shall be 54A/56A peak. 
(4) The 5V standby output shall remain on while the AC input power connected, whether DC outputs are disabled (Off) 
or enabled (On) by the remote on control signal, but when the 5V Standby output remained on with the AC input power 
turn off, the remote on control will be disabled. 
 
 
 
   
2.3 Output Ripple   
2.3.1 Ripple regulation   
 
Parameter  
Ripple&Noise  
Unit 
+3.3V  
100  
mVp-p 
+5V  
100  
mVp-p 
+12V1  
150  
mVp-p 
+12V2  
150  
mVp-p 
+12V3  
150  
mVp-p 
+12V4  
150  
mVp-p 
-12V  
150  
mVp-p 
+5VSB  
100  
mVp-p 
 
 2.3.2 Definition
 
  The ripple voltage of the outputs shall be measured at the pins of the output connector 
when terminated in the load impedance specified in figure 1. Ripple and noise are measured 
at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate 
system loading. Ripple shall be measured under any condition of line voltage, output load, line 
frequency, operation temperature.