(1) The maximum continuous total DC outputs power shall not exceed 750W.
(2) The maximum continuous load on +5V and +3.3V outputs shall not exceed 170W.
(3) The maximum combined current for the +12V outputs shall be 54A/56A peak.
(4) The 5V standby output shall remain on while the AC input power connected, whether DC outputs are disabled (Off)
or enabled (On) by the remote on control signal, but when the 5V Standby output remained on with the AC input power
turn off, the remote on control will be disabled.
(2) The maximum continuous load on +5V and +3.3V outputs shall not exceed 170W.
(3) The maximum combined current for the +12V outputs shall be 54A/56A peak.
(4) The 5V standby output shall remain on while the AC input power connected, whether DC outputs are disabled (Off)
or enabled (On) by the remote on control signal, but when the 5V Standby output remained on with the AC input power
turn off, the remote on control will be disabled.
2.3 Output Ripple
2.3.1 Ripple regulation
Parameter
Ripple&Noise
Unit
+3.3V
100
mVp-p
+5V
100
mVp-p
+12V1
150
mVp-p
+12V2
150
mVp-p
+12V3
150
mVp-p
+12V4
150
mVp-p
-12V
150
mVp-p
+5VSB
100
mVp-p
2.3.2 Definition
The ripple voltage of the outputs shall be measured at the pins of the output connector
when terminated in the load impedance specified in figure 1. Ripple and noise are measured
at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate
system loading. Ripple shall be measured under any condition of line voltage, output load, line
frequency, operation temperature.
at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate
system loading. Ripple shall be measured under any condition of line voltage, output load, line
frequency, operation temperature.