CALAMP WIRELESS NETWORKS INC. BDD4T85-2 Manual De Usuario
120 20190-001
Paragon-III Technical Manual
18
Table 4 - Checklist B (General)
CHECKLIST B (Paragon-III)
General Check out (part1 of 2)
Paragon-III units are set and characterized at the factory to optimize performances.
It is not recommended to try readjusting units unless it is really required.
Misadjusting a unit may result in significant performance losses.
The proposed adjustments in the "IF NOT?" column below, should be tried ONLY if system data
performance degradation is noticed combined with out-of-tolerance items.
Step
ACTION
Expected Results at 25
°°°°
C
MEASURE WITH
IF NOT?
1
Normal Power-up
Sequence
BDLC-III beeps once, all LEDs come ON for about four seconds, the green LEDs then
flash in a “ripple” pattern for close to two seconds. All LEDs go OFF except the CK that
should flash 6 to 8 times per second.
flash in a “ripple” pattern for close to two seconds. All LEDs go OFF except the CK that
should flash 6 to 8 times per second.
2
Connect and save unit
config
config
Press CDip Get button
as per CDip Help content
3
Transmitter Output
Power
Power
Press TX ON (Unmod)
UHF: 20 - 100 watts
800 MHz: 20 - 70 watts
+10%, -10%
Service monitor set
to read power
or
150W in-line watt-
meter installed as
close as possible
to the unit antenna
connector.
to read power
or
150W in-line watt-
meter installed as
close as possible
to the unit antenna
connector.
Adjust “Power” on the front
panel of the “Power Amp”
panel of the “Power Amp”
4
Transmitter Reflected
Power
Power
Press TXON (Unmod)
< 5% of forward power or as
specified by System Engi-
neering.
specified by System Engi-
neering.
10 W in-line
wattmeter
wattmeter
Check for bad connections,
damaged coax cable, etc.
damaged coax cable, etc.
5
Carrier Frequency Error
Press TX (Unmod)
Press TX (Unmod)
< ±300 Hz
Service monitor set
to read frequency
error
to read frequency
error
6
TX Deviation (KHz)
Press
TX (modulated)
Carrier will be modulated
with a 1 kHz tone.
with a 1 kHz tone.
Tolerance is +5%, -10% for
all bit rates.
all bit rates.
Service monitor set
to read deviation.
to read deviation.
(IF filter set to Mid
or 30 kHz position)
or 30 kHz position)
Refer to technical support
7
Low Frequency
Balance
Balance
Initiate a
TX Random data test
via CDip
via CDip
a) Record deviation level
read from step 6
b) Record deviation read
from TX Random test
c) Difference
between
a) and b) should be:
< 1.5 kHz (HC &
NPSPAC)
< 2.0 kHz (FC)
Service monitor set
to read deviation
to read deviation
(IF filter set to Mid
or 30 kHz position,
all audio filtering
disabled )
or 30 kHz position,
all audio filtering
disabled )
Refer to