CALAMP WIRELESS NETWORKS INC. BDD4T881 Manual De Usuario
120 20170-200
Paragon
PD
Technical Manual
27
CHECKLIST B (Paragon
PD
)
General Check out (part2 of 2)
Paragon
PD
units are set and characterized at the factory to optimize performances.
It is not recommended to try readjusting units unless it is really required.
Misadjusting unit may result in significant performance losses.
Step
ACTION
EXPECTED RESULTS at
25
°°°°
C
MEASURE WITH
IF NOT?
Set the service monitor to generate on the selected receive frequency. Verify alternately for both receivers.
The carrier should be modulated with a 1.0 kHz tone at deviation level specified below:
8
12 dB SINAD
(Dataradio wide band
measurement
method: no audio
filtering)
measurement
method: no audio
filtering)
- For
Full
channel
unit, set deviation
to ±3 kHz.
to ±3 kHz.
-
For Half channel
unit, set deviation
to ±1.5 kHz
unit, set deviation
to ±1.5 kHz
Better than -110 dBm
(including cable loss)
- Backplane
cor-
responding to
the receiver
being verified:
SK1, Pin 6 (see
Figure 30)
the receiver
being verified:
SK1, Pin 6 (see
Figure 30)
- Service
monitor
(IFR) set to
SINAD
SINAD
-
IFR IF filter set
to MID position
or 30 kHz wide
filter.
to MID position
or 30 kHz wide
filter.
Refer to section 6.2 for Series
I and to section 6.4 for Series
II
I and to section 6.4 for Series
II
9
Receiver distortion
(Dataradio wide band
measurement
method: no audio
filtering)
- Set
(Dataradio wide band
measurement
method: no audio
filtering)
- Set
service
monitor RF Gen
output to –70
dBm
output to –70
dBm
-
Deviation level
as per SINAD
above.
as per SINAD
above.
≤
5.5 %
- Backplane
cor-
responding to
the receiver
being verified:
SK1, Pin 6 (see
Figure 30)
the receiver
being verified:
SK1, Pin 6 (see
Figure 30)
- Service
monitor
(IFR) set to
SINAD
SINAD
-
IFR IF filter set
to MID position
or 30 kHz wide
filter.
to MID position
or 30 kHz wide
filter.
Refer to section 6.2 for Series
I and to section 6.4 for Series
II
I and to section 6.4 for Series
II
10
RSSI
-
-
Vary the RF level
output from –120
to –80 dBm
output from –120
to –80 dBm
- Measure
voltage
at each RSSI re-
ceiver ouputs
ceiver ouputs
-
2VDC @ -110dBm
- 10dB/V
±0.2V
- Backplane
cor-
responding to
the receiver
being verified:
SK1, Pin 5 (see
Figure 30)
the receiver
being verified:
SK1, Pin 5 (see
Figure 30)
- DC
Voltmeter
measurement
Refer to section 6.2.2.5 for
Series I and to sections
6.4.2.5 or 6.4.2.6 for Series II
Series I and to sections
6.4.2.5 or 6.4.2.6 for Series II