120 20180-100a Preliminary
Paragon
PD
 Technical Manual
6
2.3.1 Radio Assembly Power
Referring to Figure 3, the Radio assembly unit receives two separate 13.8 VDC power inputs from a
“T800  Slimline” dual power supply typically rack-mounted right below the main assembly radio
chassis.
The T800 is made up of two separate power supply units joined in a single chassis:
 
A T807 using convection cooling is rated up to 15A at 13.8VDC. It supplies all the radio mod-
ules other than the Power Amplifier.
 
A T808 using convection and fan cooling is rated up to 25A at 13.8VDC. It supplies only the
Power Amplifier module.
Normally used at room ambient temperatures, they can operate within their specifications over a
range of –10 to +60 °C.
Note: Internal over-temperature protection shuts down the main transformer above 105 degrees
Celsius.
Both power supply modules are internally connected to ground via their individual, rear-connected,
seven-foot standard 120 VAC power cords. Nevertheless, each requires a separate secure electrical
ground connection. Individual grounding tabs are provided next to the power connectors.
Similarly, the Radio Assembly chassis requires a secure ground connection. A threaded grounding
binding post fitted with a knurled binding-nut is provided on the chassis next to DC input 2. Separate
grounding leads with appropriate connectors are supplied (either in the courtesy small-parts kit or
with one end fastened to the equipment.
For each of the power supply modules:
1.
 
Fit one end of the grounding lead’s push-on connector onto the groun ding tab.
For the Radio Assembly chassis:
1.
 
Install the grounding lead’s lug over the binding post and firmly hand-tighten the binding-nut.
For both A and B
2.
 
Fit the slotted connector (on the other end of each of the grounding connector) under a con-
veniently located screw on the rack frame or other support surface. Scrape away paint if
needed to ensure clean contact.
3.
 
Apply anti-corrosion compound where paint scraping was done.
4.
 
Ensure by testing continuity that a secure electrical and mechanical connection is achieved.
If a –DC rail (0V) is installed as part of the system, the grounding leads may alternatively be fitted to
the rail terminal.
Caution:
Improper grounding between power supply case and rack frame may result in harmful voltage po-
tentials and/or miscellaneous power supply switching noise problems in both receivers and trans-
mitter.
Press both red power buttons located on the front of the module to have complete power distribution
to the Radio assembly. The power supply front panel LEDs indications are:
Table 2 - Power Supply LEDs Indications
LED
Color
Indication
On
Green
Power enabled *
Stby
Red
Power disabled *
OL
Steady Red
Current Overload
On & OL
Flashing green and red respectively
Over voltage
To remove voltage from the power supply PCB, disconnect the main power cords.