3.2.1.5.4 Alarm Indicators
All alarm conditions will cause the BDLC
PD+
 to light one or more of the LED indicators. LEDs remain
ON when lit until cleared by either pressing PF 1 (without affecting operation of the unit) or RESET (cy-
cling unit OFF and ON).
LM
Local Minor Alarm - when lit, indicates the presence of any of the following minor faults:
- Parity, framing or overrun error at any RS-232 port.
- Out of buffers. No memory available to accept data from a local terminal device. Usually de-
notes a flow control problem.
- Flash memory error. At power-up or reset, the unit detected a change in non-volatile memory.
RM
Remote Minor Alarm - when lit, indicates any of the Local Minor Alarm listed above have taken
place at the remote end of the link (i.e. the mobile the local base station is currently communi-
cating with). It will also light when a protocol error has been detected on the network.
In a network using the “Host Link Active” (MSC) feature, the RM LED, flashing in-sync with
the CK LED, indicates that the link is down.
LF
Link Failure - when lit, indicates that the base station fails to receive an ACK for a packet sent
and for all subsequent retries. Some data has possibly been lost. LF is not functional if all active
ports are set to NAR mode.
Link fails are inevitable during normal operation (mobiles temporarily out of range, in a tunnel,
parked in a dead spot, etc.). A lit LF LED is not normally cause for concern.
UF
Unit Failure - when lit, the unit requires attention:
 - The BDLC
PD+
 is not operable;
It may indicate detection of a system software error trap.
- The BDLC
PD+
 is operable;
Indicates that on power-up, invalid data was detected in the serial EEPROM chip (located in the
radio modules). It may also indicate that connection to the radio
modules is incorrect or that radio power is not applied.
The LMRM and UF alarms also sound a beep when a fault occurs. The LF
alarm is silent.
                                                                                    Figure 14 - ALARMS LED indicators
3.2.2 BDLC
PD+
 Rear panel
Referring to Figure 4, the rear panel of the BDLC
PD+
 has the following set of chassis connectors:
 
One DB-25F connector
 
DEV1 - Connects to user’s applic ation.
a)
 
DMP 19200 or 38400 baud for single-site installations
b)
 
MSCP 19200 or 38400 baud for multi-site installations
 
Four DE-9F connectors:
 
DEV2 - usually connected to Dataradio’s WinRIS program  (Dedicated or DMP at 19200 baud).
 
DEV3 - Dedicated (up-to 9600 baud)
 
DEV4 and DEV5 - not used
 
One DA-15M connector:
ALARMS
LM RM LF UF