CALAMP WIRELESS NETWORKS INC. BDD4T881-3 Manual De Usuario

Descargar
Página de 58
120 20180-100a Preliminary
Paragon
PD+
 Technical Manual
38
6.
 
For multi-channel unit, select the highest frequency channel. Transmit a square wave by pressing
the BDLC
PD+
’s PF1 button and following the procedure outlined in section 3.2.1.3. Record de-
viation again.
7.
 
The difference in deviation between the two channels should be less than ±300Hz. If not, re-
adjust IC220 to "average" the square wave shape on both channels until the spec is met.
8.
 
To confirm the adjustment, select the active, or the lowest frequency channel. Compare the de-
viation produced between 1000 Hz sine wave test tone and Random data test pattern
The difference between the test tone and the test pattern should be:
-
 
< 600 Hz (DGMSK)
-
 
< 1.5 kHz (xRC4FSK, xRC8FSK, HC)
-
 
< 2.0 kHz (xRC4FSK, xRC8FSK, FC/NPSPAC).
For multi-channel unit, repeat this step on the highest frequency channel.
9.
 
Select the active channel. Transmit a TX ON (Modulated) adjustment tone by pressing the
BDLC
PD
’s PF1 button and following the procedure outlined in section  3.2.1.3. Make sure that
deviation level read on the IFR correspond to model and bit rate in use (see Figure 16). Re-adjust
deviation as necessary referring to Checklist B at step 6, page 23.
5.2.3.5 Exciter Power Output
1.
 
Apply the following settings to the IFR:
-
 
Receiver mode, Output T/R
-
 
IFR RX frequency to match the main radio TX frequency
-
 
IF Filter set to 30KHz
-
 
Select auto range in the Power reading window
-
 
Connect the coaxial cable from the IFR T/R to the Exciter output connector
2.
 
Key the Exciter by pressing the module PTT button. The output power at the coaxial cable end
connecting to the power amplifier should be:
-
 
VHF (T837) = 800 mW ±200mW (no adjustment provided)
-
 
UHF (T857) = 1W ±300mW (no adjustment provided)
-
 
800/900 MHz (T881) = 4W ±300mW (RV502, Figure 28)
5.2.4 Power Amplifier Module (T889 (800-870 MHz only), T859 or T839)
-
 
Re-install the exciter module into the Paragon
PD+
 rack frame.
-
 
Connect the Exciter module to the Power Amplifier.
-
 
Connect the Power Amplifier output to the IFR T/R connector or to a stand-alone BIRD style
power meter, terminated with a 150W dummy load.
-
 
Forward and reverse power alarm set (control) are identified on the PA cover.
Note: 
For the TPL Communications Power Amplifier (PA8-2BF-LMS) adjustment, see sec-
tion 5.2.5
5.2.4.1 Power Amplifier Power Output
-
 
Key the transmitter on the exciter and adjust the PA output for required output (max 100W for
VHF and UHF and max 70W for 800) using the front panel power control
If power cannot be reached, refer to section 5.2.4.4 for T859 UHF model, or factory technical
support for T839 and T889 models. Cable loss should be included in the reading.