CALAMP WIRELESS NETWORKS INC. BDP3-AMP Manual De Usuario

Descargar
Página de 49
120 20191-100a
Paragon-III User Manual
16
3.1.7  Radio Backplane Assembly
Figure 14 - Radio Backplane Assembly
3.2  Online & Offline Diagnostics
Paragon-III units continually monitor and report on their environmental and operating conditions. Each
transmission carries online diagnostic information which can be monitored remotely or even sent to a
designated host for logging and later analysis. Transmission of online diagnostics may be enabled or dis-
abled at any station or stations without affecting their ability to communicate with other stations
Additional information, statistics, and offline test facilities are available via the browser. RF paths can be
monitored and checked from either end of a link, without travelling to the other station.
Power Amplifier
13.8 VDC
Maxi-Fuse 10A
2 Maxi-Fuses 15A
DE-9 for Remote control or
remote sense functions
RJ-45 connector
Used for
programming
System 13.8 VDC
Pin 1
F1
F3