120 20195-100 Preliminary
Paragon4 – UHF, 700, & 800MHz User Manual
22
Table 4 - Checklist B (General)
CHECKLIST B (
Paragon4
)
General Check out (part1 of 2)
Paragon4 units are set and characterized at the factory to optimize performances. 
It is not recommended to try readjusting units unless it is really required. 
Misadjusting a unit may result in significant performance losses.
The proposed adjustments in the "IF NOT?" column below, should be tried ONLY if system data per-
formance degradation is noticed combined with out-of-tolerance items.
Step
ACTION
Expected Results at
25
°C
MEASURE WITH
IF NOT?
Normal Power-up 
Sequence
BSC
PWR LED lights red for four seconds, turns amber for one second, and stays green
thereafter. 
TX LED flashes green once about fifteen seconds after power-up then keeps flashing
in-tune to the cycle marker
RX LED remains OFF
STATUS LED remains OFF     
ETH 1 LED – if connection present – lights green. Flashes amber with activity
ETH 2 LED – If connection present – lights green. Flashes amber with activity
RX1 and  RX2
PWR LED remains steady green
1
Transmitter
PWR LED and LOCK LED remain steady green 
ON LED  lights red after 10 seconds,  and stays red thereafter
For steps below, on the Radio Î Set Up Web page, press the “test” button to enable Test Tone function
2
Transmitter Output Power
From the Maintenance unit
WEB “Test Tone” page,
Select Unmodulated –
Press Execute
UHF: 100 watts
800 MHz: 70 watts
(user settable from 20W)
Tolerance: +15%   -20%
Service monitor set to read
power
or
150W in-line wattmeter
installed as close as
possible to the unit antenna
connector.
Adjust “Power” on the
“Power Amp”. See
Power Amplifier ad-
justments paragraph in
PA’s manual.
3
Transmitter  Reflected 
Under Test Tone section
select
Unmodulated 
and press “Execute”.
< 5% of forward power or as
specified by System Engi-
neering. 
10 W in-line wattmeter
Check for bad connec-
tions, damaged coax
cable, etc.
4
RF Link test between Paragon4 unit and mobile unit(s) (PING test from the unit Web page as per para-
graph Error! Reference source not found. or PING from a PC as per paragraph 5.4.1)
5
Carrier Frequency Error
Under Test Tone section
select
Unmodulated 
and press “Execute”.
< ±300 Hz  @ 25
o
C ambient
or
< ±1 ppm from –30 to +60
 o
C
< ±0.1
1)
 ppm  –30 to +60
 o
C
Service monitor set to read
frequency error. 
1)
0.1 ppm
requires the 10MHz refer-
ence option to be present
and instrument’s time gate
set to 1s
Adjust frequency offset
through the software 
6
TX Deviation (kHz)
 Under Test Tone section
 select
  Unmodulated 
and press “Execute”.
Carrier will be modulated with
a 1 kHz tone.
Refer to 5.3.1 for TX
Deviation details.
Tolerance is +5%,
-10% for all bit rates.
Service monitor set to read
deviation.
(IF filter set to Mid or 30
kHz position)
If transmitter is re-
tuned outside its
original factory-
calibrated tuning range
or where its deviation
readings are found to
be out-of-specs, please
contact Dataradio
System Engineering.