RF1100 | Installation Instructions | 1.0  Installation Considerations 
 
Bosch Security Systems | 7/04 | 4998138680B 
 
1.0 Installation 
Considerations 
Mount the RF1100 on flat surfaces such as ceilings and 
walls. Mount the unit to optimize glass break detection. 
Refer to Figure 2 and Figure 3 for mounting examples. 
In normal residential or commercial applications, 
locate the RF1100 within 325 ft (100 m) of its assigned 
receiver. 
 
 
For best detector performance, select a 
mounting location that is: 
 
within 25 ft (7.6 m) of the protected 
glass 
 
within clear view of the protected 
glass (there is no minimum range) 
 
at least 6.5 ft (2 m) from the floor 
 
at least 3.3 ft (1 m) from forced-air 
ducts 
 
at least 3.3 ft (1 m) from sirens or 
bells (greater than 2 in. [5 cm] in 
diameter) 
 
mounted on a window frame if any 
heavy window covering is present 
 
 
 
Avoid mounting the detector: 
 
in a corner 
 
on the same wall as the protected 
glass 
 
on free-standing posts or pillars 
 
in rooms with noisy equipment such as 
air compressors, bells, and power tools 
 
 
Test the detector in the desired mounting 
location before drilling mounting holes. 
Refer to Section 2.2 Testing on page 5. 
The RF1100’s maximum outside RF range is 
approximately 1000 ft (300 m). 
 
Figure 2:  Wall Mounting Locations (top view) 
7
5
1
2
4
3
6
3
3
 
1 -   Poor location - 
fully opened door 
can block 
detector’s range
3
 
2 -   Poor location - 
high risk of door 
slam noise
3
  
3 -   25 ft (7.6 m) 
maximum 
mounting distance 
4 -   Window 
5 -   Best locations
1
 
6 -  Satisfactory 
location
2
 
7 -   Satisfactory 
location if a heavy 
window covering 
is present
2
 
 
Figure 3:  Ceiling Mounting Locations (side view) 
1
4
3
5
2
 
1 -   Best 
locations
1
 
2 -   Ceiling 
3 -   25 ft (7.6 m) maximum 
mounting distance 
4 -  Glass 
5 -   Floor 
 
1  Best location: where the RF1100 is most effective. 
2  Satisfactory location: where the effectiveness of the RF1100 can 
be reduced.  
3  Poor location: where the effectiveness of the RF1100 is impaired.