DS840LSN | Installation Guide | 4. 
Wiring
EN | 5
Bosch Security Systems | 9/03 | PRELIMINARY 4998132113Ar11
4. Wiring
Apply power ONLY after all connections
have been made and inspected. Do NOT
coil excess wiring inside the detector.
Figure 5: DS840LSN Terminals
1
2
3
4
1 -
aLSN1 & bLSN1: coming from the preceding
LSN element. Shielded cable is recommended
for bus connections
2 -
aLSN2 & bLSN2: going to the next LSN
element. Shielded cable is recommended for
bus connections.
3 -
5 & 6: Spare terminals.
4 -
7: Connection for ground wire from shielded
cable.
Do not coil excess wire inside the
enclosure.
Plug the wire entrance hole with the foam
plug provided after all wiring connections
have been made.
5. LED 
Operation
The detector uses 3 colored LEDs to indicate the
various alarm and supervision trouble conditions that
that exist. See Table 2.
Table 2:
Status of LEDs
Walk
Test
Status
Condition
Red
Yellow
Green
Disabled
All
Off
Off
Off
Power-Up
Sequential Green, Yellow, Red
Flashing
Dual Alarm
Flashing
Off
Off
Microwave
Alarm
Off
Flashing
Off
PIR Alarm
Off
Off
Flashing
Enabled
No Activity
Off
Off
Off
During walk testing, the LEDs light for the first
technology (microwave or PIR) and then light red to
indicate a detector alarm. The LEDs will not indicate
activation of the second technology with color.
If the detector experiences a Microwave or PIR self-test
failure, it is in need of replacement.
6. Mirror 
Alignment
1.
 
Select the vertical mirror angle from Table 3 to
match the mounting height and desired maximum
coverage.
Table 3:
Broad Coverage Mirror
Maximum Coverage Distance
Mounting
Height
7.5 m (25 ft.)
12 m (40 ft.)
2.0 m (6.5 ft.)
-6
°
 *
-4
°
 *
2.3 m (7.4 ft.)
-10
°
-8
°
2.6 m (8.5 ft.)
-12
°
-8
°
* = Required Settings for Pet Applications
2.
 
The angle adjust markings are on the mirror. Push
in on the bottom or top of the mirror assembly to
position the angle hash marks with the markers on
each side of the frame (Figure 6) based on the
values in Table 3.