S ec ti o n   2 . 3 :   C h a n g i n g   O t h e r  N T 9 0 10   F u n c t i o n s
3 9
• Wireless Zone   Determines if the zone is a wireless zone or a hardwired zone. 
Allows the system to generate low battery trouble and zone supervisories.
NOTE:
 The wireless zone attribute must be enabled for all enrolled wire-
less zones. 
Audible/Silent Alarm  . . . . . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [1]
Pulsed/Steady Alarm  . . . . . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [2] 
Activate Chime  . . . . . . . . . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [3] 
Bypass Enable  . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [4] 
Force Arm Enable  . . . . . . . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [5] 
Swinger Shutdown Enable . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [6] 
Transmission Delay Enable . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [7]
Wireless Zone  . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [101] to [132], Option [8]
2.3.3
Enrolling 
Hardwired 
Zones
You can install up to two hardwired zones on the NT9010 system. To make the wir-
ing connections for these zones, please see Connecting Zone Wiring – Hard-
wired
 on page 7. You must also enroll the hardwired zones on the system. 
To do this, in Flash Programming enter serial number [200001] for the first hard-
wired zone, and [200002] for the second hardwired zone. The NT9010 system will 
automatically assign the hardwired zone to the next available zone number. 
If you need to change the zone assignment of the hardwired zones, you can do this 
in the Advanced programming sections:
1. Enter programming section [807].
2. Enter sub-section [091] for the first hardwired zone, or sub-section [092] for the 
second hardwired zone.
3. Enter the 2-digit number of the zone that will be hardwired. 
NOTE:
 Entering a zone as a hardwired zone will override any wireless 
device serial number that may be programmed for the zone.
NOTE:
 Fire zones are not supported as hardwired zones.
2.3.4
Wireless 
Device Serial 
Numbers
Normally, you will use the NT9010 Flash Programming to enter device serial num-
bers. If you need to delete a device from a zone, or replace a device, you can use 
the advanced programming section. To add, replace, or delete devices:
1. From Installer’s Programming, enter section [804]
2. Enter the 2-digit number of the zone you want to delete (01 - 32). The system 
announces the current serial number for the zone.
3. Enter the new serial number for the zone. To delete a device, enter [000000]. 
The wireless device for the zone will be removed.
NOTE:
 You may need to remove power from the system and then restore 