Belt Clip Assembly:
1. Remove the tear away cap from the clear plastic housing.
2. Break off the plastic tab that is permanently affixed to the top of the clear
plastic housing of the pendant.
3. Snap on the belt clip cap.
4. Put the battery into the pendant (please see ‘Replacing the Battery’ for proper
orientation).
5. Insert the clear plastic housing into the rubber boot
Testing the WLS918
The pendant should be tested on a weekly basis along with the rest of the alarm
system.  For full system testing instructions, please consult your control panel
Instruction Manual.
To Test the Pendant:
1. Begin testing when your system is in the ready state and the keypad Ready
(Green) light is ON.
2. Press and hold either of the 2 buttons for 5 seconds.  When the button has
been held long enough the LED in the pendant will turn ON steady for 2
seconds.  Once the test transmission signal from the pendant has been
received by the alarm system and the pendant’s battery condition is normal,
the Ready light of the keypad will turn OFF for approx. 5 seconds.
3. If the pendant’s battery is low, the keypad Trouble (yellow) Light will turn ON
and a series of continuous keypad beeps will be heard.
Signals will not be received and processed if the pendant is not within
range of the alarm system.
When the WLS918 has a low battery, it will flash the LED once every 10
seconds until the battery is replaced.
When the unit detects a low battery, it will flash the LED once every 10
seconds until the battery is replaced.
Activating an Alarm
An alarm can be generated via the WLS918 in a few different ways:
1. Press and hold both buttons simultaneously for 2 seconds  or
2. When using the tear away version, pull down on the unit until the cap breaks
away from the body of the WLS918 or
3. When using the belt clip version, pull down on the unit until the cap breaks
away from the body of the WLS918.
Replacing the Battery
1. Remove the rubber boot that covers the clear plastic housing. You can do this
by placing your fingernails in between the top of the rubber boot and the
bottom of the plastic cap then pull up on the plastic and down on the boot to
separate them.
2. Remove the plastic battery cover at the bottom of the plastic housing.
3. Pull out the old lithium battery.
4. Insert the new lithium battery ensuring that the negative side of the battery
faces the green PCB (printed circuit board).
5. Replace the battery cover.
6. Insert the clear plastic housing back into the rubber boot.
7. Test the WLS918 as per the testing instructions.
 
Only use battery type FDK CR2032 as a replacement for this product.
 
The polarity of the batteries must be observed, as shown in the
diagram above. Improper handling of lithium batteries may result in
heat generation, explosion or fire, which may lead to personal injuries.
WARNING: DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED
INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER.
Keep away from small children.  If batteries are swallowed, promptly see a doctor.
Do not try to recharge these batteries.  Disposal of used batteries must be made in
accordance with the waste recovery and recycling regulations in your area.
+
F D K
LITHIUM BA
TTER
CR2032
3V
+
F D K
LITHIUM BA
TTER
CR2032
3V
+