Digital Security Controls Ltd. 02CL3050 Manual De Usuario

Descargar
Página de 28
1 Introduction
1
1 Introduction
The Skyroute CL3050 is a standalone wireless communicator that sends alarm system infor-
mation to Connect 24. Connect 24 then forwards this information to the central station. 
The Skyroute CL3050 automatically configures itself on power up to one of three opera-
tional modes or; if it is connected to a keypad, in the programming mode. The Skyroute 
CL3050 is pre programmed with the most commonly used settings for quick installation. If 
required the default options can be custom programmed.
Mode 1: Bell Follower 
If the Skyroute CL3050 does not detect a keypad or PC5108 expander card dur-
ing the first 15 seconds of power up, then mode 1 or 2 can be selected by press-
ing the enroll button. The red LED indicates Mode 1 and the yellow LED indicates 
mode 2. In Mode 1, the Skyroute CL3050 monitors the Bell Output of the con-
trol panel. The system identifies the Bell Output cadence and transmits the corre-
sponding Fire or Burglar alarm reporting code to Connect 24.
Refer to the appropriate control panel Installation Manual.
Mode 2: 2-Zone Panel 
If Mode 2 is selected during power up the system will configure itself for 2 zone, 
stand alone operation with normally closed loops.
Mode 3: 8-Zone Panel
If the Skyroute CL3050 detects a PC5108 expander card on power up it will auto-
matically configure itself for 8-zone standalone operation with normally closed 
loops.
Programming Mode 
If the Skyroute CL3050 detects a keypad on power up it will go into the program-
ming mode. Programming mode allows the installer to custom program system 
options. Refer to Section 5, Programming Descriptions; and Section 6, Program-
ming Worksheets for programming options and default settings.
Note:
The only method of entering the Programming Mode is to power-down the unit, 
connect a PowerSeries keypad to the Keybus terminals, then reapply power to 
the Skyroute CL3050.
Figure 1