Digital Security Controls Ltd. 15TL2553GRE Manual De Usuario

Descargar
Página de 38
HEX
Value
Offset
Hours
Standard
Abbreviation
Location
4D
7
BDT
Bangladesh Standard Time
51
8
CST
China Standard Time
52
8.25
APO
Apo Island Time
54
8.75
ACWST
Australian Central Western Standard Time
55
9
KST
Korea Standard Time
57
9.5
ACST
Australian Central Standard Time
59
10
AEST
Australian Eastern Standard Time
5B
10.5
LHST
Lord Howe Standard Time
5D
11
VUT
Vanuatu Time
5F
11.5
NFT
Norfolk Island Time
61
12
NZST
New Zealand Standard Time
64
12.75
CHAST
Chatham Island Standard Time
65
13
TOT
Tonga Time
69
14
LINT
Line Island Time
70-FF
N/A
N/A
N/A
[021] Account Code
Default (FFFFFF)
The account code is included when transmitting any events generated by the Communicator. (e.g., Panel Absent Trouble). It is
recommended that the account code be the same as the control panel account number. Valid range: 000001-FFFFFE. If 4 digit
account codes are needed the 2 lowest digits shall be programmed as FF.
(e.g., Account 1234 is programmed as:1234FF).
NOTE: Programming this Section with all 0 or F will cause a Module Configuration Trouble.
[022] Communications Format
Default (04)
Program 03 for Contact ID (CID). Program 04 for SIA. The module can be configured to send Events in SIA or CID format. The
SIA communication format follows the level 2 specifications of the SIA Digital Communication Standard - October 1997. This
format will send the account code along with its data transmission. The transmission will look similar to the following at the
receiver. Example: Nri0 ET001
Where: = New Event; ri0 = Partition/Area identifier; ET = Panel Absent Trouble; 001 = Zone 001.
Communications Reporting Codes
Table 9: Communications Reporting Codes
Event
SIA
Identifier
SIA
Reporting Code
CID
Qualifier
CID
Event Code
CID
Reporting Code
CID
User/ Zone
[023] Panel Absent Trouble
ET
001
1
3
55
001
[024] Panel Absent Trouble Restore
ER
001
3
3
55
001
[025] Radio Activation Restore
RS
001
3
5
52
001
[026] Ethernet 1 Test Transmission
RP
001
1
6
A3
951
[027] Ethernet 2 Test Transmission
RP
002
1
6
A3
952
[028] Cellular 1 Test Transmission
RP
003
1
6
A3
955
[029] Cellular 2 Test Transmission
RP
004
1
6
A3
956
[030] FTC Restore
YK
001
3
3
54
001
[023] Panel Absent Trouble
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the panel have been lost for
more than 60 seconds.
[024] Panel Absent Trouble Restore
Default (FF)
16