Connecting Cables in a Dual-Bay RF Module Installation
1
Position the cables so that they are under the right edge of the RF Module, pointing up.
2
Follow the rules listed in 
.
3
Working from the bottom connector up, connect the RF Module cables, as described below. As you work, refer 
to the graphic that corresponds to the RF Module being installed in the Dual-Bay: for a Dual-Bay RF Module, 
refer to 
, and for a Legacy Dual-Bay 40W RF Module, refer to 
a
Connect the MOD N TX1/RX1 cable to the N-Style RF connector on the Dual-Bay RF Module (the RF cables 
and connectors are referred to as MOD N TX1/RX1 where N equals BC, or D).
i
Constrain the MOD N TX1/RX1 cable of the lower RF Module bay to accompanying cables using a tie 
wrap so it cannot be pinched or prevent the Remote Unit door from closing.
ii
Connect the MOD N TX1/RX1 cable to the TX1/RX1 N-Style Jack of the upper RF Module Bay.
iii Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.
iv Torque coupling nut to 8 ±1 in-lbs to ensure full connection.
NOTE:
Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and 
higher than normal VSWR reported by the system.
b
Connect the MOD N TX0/RX0 cable to the RF Module (the RF cables and connectors are referred to as 
MOD N TX0/RX0 where N equals ABC, or D).
i
Insert the N-Style Plug of the MOD N TX0/RX0 cable into the TX0/RX0 N-Style Jack of the lower RF 
Module  bay.  If  RF  Module  connection  is  not  available,  constrain  the  MOD  N  TX0/RX0  cable  to 
accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from 
closing.
ii
Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.
iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.
NOTE:
Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and 
higher than normal VSWR reported by the system.
c
Connect the LVDS Cables to the RF Module.
i
If available, connect the MOD N DIV LVDS Cable to the DIV receptacle of the lower RF Module by 
inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the MOD N DIV 
LVDS Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote 
Unit  door  from  closing.  Full  insertion  can  be  recognized  by  an  audible  click  as  the  LVDS  Cable 
Connector locks into the RF Module Receptacle.
ii
Connect the MOD N DIV LVDS Cable to the DIV receptacle of the upper RF Module by inserting and 
sliding in until fully seated. If DIV receptacle is not available, constrain the MOD N DIV LVDS Cable to 
accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from 
closing. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into 
the RF Module Receptacle.