Badger Meter Inc 2002C Manual De Usuario

Descargar
Página de 2
®
Due to continuous research, product improvements and enhancements,
Badger Meter reserves the right to change product or system specifications
without notice, except to the extent an outstanding bid obligation exists.
Copyright © Badger Meter, Inc. 2002. All rights reserved.
Please see our website at
www.badgermeter.com
for specific contacts.
BadgerMeter,Inc.
P.O.  Box   245036,  Milwaukee,  WI  53224-9536
(800) 876-3837 / Fax: (888) 371-5982
www.badgermeter.com
Badger
®
, ORION
®
, Recordall
®  
and RTR
®
 are registered trademarks of Badger Meter, Inc.
TORX
®
 is a registered trademark of Camcar, Division of Textron, Inc.
MOISTURE:  The RTR is permanently sealed and designed for
submerged meter pit applications.  The RTR Pit ORION system is also
designed for flooded or submerged meter pit locations.
WIRE CONNECTIONS: The RTR can be factory prewired with pre-
sized wire harness of either 5 or 20 feet to the ORION Pit Module.
ELECTRONICS: The piezoelectric switch circuit board is completely
sealed against moisture inside the unit and sealed to ensure protection
from humidity.  The Pit ORION Module is designed to protect against
the effects of humidity.
ELECTRICAL:  The electronic circuitry of the RTR and Pit ORION
Module is designed to provide immunity to electrical surges and
transients per IEC801-2, IEC801-4 Severity Level 4.
OPERATING CHARACTERISTICS:  The RTR has an output equal
to 1/10th of the meter test circle with the characteristics of an open drain
FET. The on-state condition is a solid-state switch closure. Off-state
condition is an open circuit. Powered by an external source, the RTR
has a maximum rating of 30 VDC at 1 mA (25°C).
PATENT: The Badger RTR Pit ORION application is covered by US
patent number 5,298,894.
TRANSPORTATION WARNING:  The Federal Aviation Administration
prohibits operating transmitters and receivers on all commercial
aircraft.  When powered, the Pit ORION Module is considered an
operating transmitter and receiver and cannot be shipped by air.
MEASUREMENT RESOLUTION:  The minimum electronic resolution
of the RTR is noted to the right.  To verify the correct resolution for your
application, contact Badger Meter Customer Solutions.
METER COMPATIBILITY: Badger Meter's Recordall
®
 Disc, Turbo,
Compound, and Fire Series meters.
Resolution
Resolution
RECORDALL
Cubic
Cubic
Model
Size
Gallons
Feet (Ft
3
)
Meters (m
3
)
M25
5/8"
1
0.1
0.01
M25
3/4"
1
0.1
0.01
M35
3/4"
1
0.1
0.01
M70
1"
1
0.1
0.01
M120
1 1/2"
10
1
0.1
M170
2"
10
1
0.1
RECORDALL
Resolution
Resolution
Turbo Series
Cubic
Cubic
(Size)
Gallons
Feet (Ft
3
)
Meters (m
3
)
2"
100
10
0.1
3"
100
10
0.1
4"
100
10
0.1
6"
100
10
1
8"
100
10
1
10"
100
10
12"
1000
100
16"
1000
100
20"
1000
100
LICENSE REQUIREMENTS
This device complies with Part 15 of the FCC Rules.  Operation of this
device is subject to the following two conditions:  (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.  Any changes made by the user not approved by Badger
Meter can void the user's authority to operate the equipment. No license
is required by the utility to operate a ORION meter reading system.