1-11
Installation & Operation Manual
If you choose Trouble Code, the Trimble Ranger will return to the Tamper Menu screen once the code is entered and stored so 
that you can also enter a manual reading.  
If you choose to enter a Manual Read, you’ll see this screen:
Enter the reading and press the “Enter” button or select the “OK” RIGHT Soft Menu key.  If you wish to skip the manual read, 
select the “Cancel” LEFT Soft Menu key.
When you have completed entries for this meter, press the ”OK”  LEFT Soft Menu key.  The handheld will be returned to the 
read screen in automatic mode.
Clearing a Tamper
If a Badger Meter Meter ORION® endpoint reports a tamper condition, you must perform maintenance on the unit to clear the 
tamper condition.  Once the condition that caused the tamper is cleared, the unit must be reprogrammed if it is connected to 
a Badger Meter Recordall Endpoint Register (RTR) using the ORION programming tool.  If the Badger Meter ORION endpoint 
is connected to a position-based encoder like Badger Meter’s Absolute Digital Encoder (ADE®), no programming is required.  
Successfully resetting the odometer value will clear the tamper report.  Please refer to the Badger Meter ORION PROGRAM-
MING section for more information.
Processing Encoder Errors
If the meter being displayed reports an encoder error, you will hear a special sound and see the following screen: