Installation Manual
Activating the Endpoint
ORION Metal Lid endpoints are shipped in an inactive, non-transmitting state known as “Pause” mode . 
NOTE:
N
Endpoints shipped via air are shipped in “Stop” (hard sleep) mode and must be activated via infrared (IR) 
communication using an ORION handheld or mobile reading system and the ORION Endpoint Utility software .
RTR
When an RTR is mounted on the water meter, and the ORION Metal Lid endpoint is connected to the RTR for the first time, 
the endpoint will register a tamper, which must be cleared before the ORION system is ready for operation . Use the ORION 
handheld or mobile meter reading equipment to program and set the endpoint odometer value . 
HR-E or ADE 
When an HR-E or ADE is mounted on the water meter, and the ORION endpoint connected to the encoder is securely installed, 
the ORION system is ready for operation . The endpoint will turn on with water usage . It requires up to one fifteen minute 
reading interval where consumption changes the electronic reading . For example, with an ORION endpoint connected to 
an eight-dial HR-E or six-dial ADE, 
the encoder must detect consumption of 10 gallons over a fifteen minute reading period  
before the endpoint will begin broadcasting data . Once the endpoint begins broadcasting, it will update hourly based on the 
encoder odometer reading . No specific wire testing or endpoint programming is required . 
NOTE:
N
Reading an ORION endpoint with the ORION handheld or mobile meter reading equipment immediately after 
installation verifies proper operation and reading performance . 
High Resolution ELCD Encoder or E-Series Ultrasonic Meter
When an HR-ELCD encoder is mounted on the water meter, or when an E-Series Ultrasonic meter is installed, and the ORION 
endpoint connected to the encoder or E-Series Ultrasonic meter is securely installed, the ORION system is ready for operation . 
The endpoint will turn on with water usage . When using consumption, the endpoint requires one fifteen minute interval 
where the least significant digit on the encoder changes before it will begin broadcasting data . Once the endpoint has begun 
broadcasting, it will update hourly based on the HR-E LCD encoder or High Resolution E-Series Ultrasonic meter odometer 
reading . No specific wire testing or endpoint programming is required . 
NOTE:
N
Reading an ORION endpoint with the ORION handheld or mobile meter reading equipment immediately after 
installation verifies proper operation and reading performance . 
Confirming an Installation
Before leaving the installation site, the installer can use an ORION handheld or mobile reading system to confirm the endpoint 
wiring has been done correctly and that the endpoint is broadcasting RF data for reading . See the appropriate handheld or 
mobile reading system user manuals for more information .  