Badger Meter Inc 2014GWGAL Manual De Usuario
Installation Manual
Figure 13: Stripped cable wires
3 . Shorten the foil shield flush with the outer jacket .
4 . Strip the ends of the six (6) colored wires to a length of 1/8 inch . Twist the conductors on each wire .
5 . Shorten the drain/bare wire (no insulation) to 11/16 inch .
6 . Loosen each screw (about 2…3 turns) on the female insert and attach the wires to the insert using the chart below .
4 . Strip the ends of the six (6) colored wires to a length of 1/8 inch . Twist the conductors on each wire .
5 . Shorten the drain/bare wire (no insulation) to 11/16 inch .
6 . Loosen each screw (about 2…3 turns) on the female insert and attach the wires to the insert using the chart below .
Retighten each screw after the wire has been connected .
Function
Wire
Female insert connector
Female Insert Diagram - Top View
Female Insert Photo - Top View
RS232
White
4
V DC–
Drain
8 (center)
V DC–
Black
3
V DC+
Blue
7
V DC+
Red
1
RS232
Green
5
V DC–
Brown
2
Not used
Not
used
6
* Used with the serial programming harness ( 66529-002)
**For use with shielded cable only
**For use with shielded cable only
7 . Assemble the insert by aligning the female insert tab slot with the notch in the coupling sleeve .
Figure 14: Slot alignment
Insert Tab Slot
Coupling Sleeve
Insert Notch
Slot
Brown
Red
Black
Blue
White
Not
Used
Green
Drain
Page 15
February 2014