Badger Meter Inc BADGERAM Manual De Usuario

Descargar
Página de 10
5
ORION
®
 Integral Transmitters/Hardcase
Gas Meter Identification
ORION integral transmitters for gas meters
are designed for use with a variety of major
brands of hardcase gas meters. Please refer
to and use the following identification table.
Identification Table
Installation of ORION Integral Transmitter
This manual describes installing the ORION
transmitter and index on Sensus, American,
and Actaris gas meters.
ORION
®
Gas Meter Manufacturer
Gas Meter Model
Transmitter #
Sensus
®
/Invensys
®
/
R-175/200/250/275
Rockwell
®
/Equimeter
®
 
Meters
11 tooth
64989-001
American
®
 Meter
AL-175/250/425/630
64989-002
Actaris
®
 
Slope Face Meter
      175/250/400
64989-003
Actaris
®
 
Straight Face Meter
      175/250/400
64989-004
Installation Tools and Materials
Use magnetized screwdrivers.
1/8" flat screwdriver
¼”   flat screwdriver
#1   Phillips screwdriver
Radix
®
 Hand Held
or
Optical Programming Probe and Laptop
computer
Label Information
Certification markings are noted on the
product label. Label markings include:
Model number 65512-003                08-2005
are completed with proper numbers printed at
 003         08-2005.
Battery SAFT LS26500 is a 3.6V Lithium C
cell.
Battery SAFT LSI7500 is a 3.6V Lithium A
cell.