Badger Meter Inc BADGERCA Manual De Usuario

Descargar
Página de 16
12
Step B: Place a new serial number tag
above the one that is on the transmitter.
Step C: Place the cover plate back on the
transmitter.
Badger
®
 ORION
®
 Transmitter Label
Step A: With a needle nose pliers pull the
plastic cover plate down and off.
If the utility chooses to add an additional
label, follow steps A, B, and C below. If
not, go to Install in the next column.
Serial Number
Label
Step 2: When mounting a Badger ORION
transmitter to a gas meter, make sure the
transmitter drive pawl engages the gas meter
drive pawl. These two drive pawls must mate
without causing any binding or potential for
disengagement.
Test to ensure the pawls are engaged and
moving freely.
Install the Badger ORION Transmitter and
American Cover Plate
Use care when handling the Badger ORION
transmitter to insure the drive pawl is not
subjected to any physical abuse. Abuse may
cause this spindle to become bent, misaligned or
otherwise inoperative.
When attaching a Badger ORION transmitter to a
gas meter make sure it mounts securely to the
meter.
Step 1: Place the Badger ORION transmitter on
top of the gas meter, where the index and index
cover plate were previously removed.
Place the transmitter drive pawl so it is
perpendicular to the meter drive pawl.
Drive Pawl
Spindle
Meter
Drive Pawl
Transmitter
Drive Pawl
placing transmitter on
meter incorrectly may
damage the output seal of
the gas meter.