Installation & Operation Manual
ORION CE
To access the Quick Read and Programming functions for ORION CE endpoints, tap ORION CE on the Program & Quick Read
main menu. The ORION CE Utility is divided into five tabs: IR Programming, RF, RF S/N, Settings and About.
IR Programming
Using the functions on the IR Programming tab, you can start, stop, pause and program ORION CE endpoints. An endpoint
connected to an RTR with a tamper (cut wires between the endpoint and the RTR) will need to be programmed after the
wires are repaired.
Note: An ORION endpoint connected to an ADE (or approved competitor encoder) does not require programming if the
wires are cut. The endpoint will update itself with the new encoder reading in the first hour after the wires have been
repaired.
Programming Functions
The Program screen includes these functions:
Read
Exports data (read and status) from the endpoint through the optical LED.
Program
Changes the odometer or clears a tamper.
HPwr
Highpower forces a brief high powered signal so an endpoint will report to a gateway.
Odometer
Registers the amount of water flowing through the meter.
Stop
Stops the endpoint from sending a signal until it is programmed again.
Pause
Stops the endpoint temporarily until a unit of water is registered. (Common practice of seasonal users.)
Start
Starts the radio transmission on an endpoint.
Listen
Switches to RF and "hears" the endpoint if it is active.
Drive Circle?
Used for gas meters only.
ORION RF and IR COM Settings
At the bottom of all the Quick Read & Program screens for the ORION CE Utility, the reading technology,ORION RF and IR, are
displayed. If the background color is green, the correct COM (communication) ports have been set.
If the COM port is not set correctly, the field changes. For example, RF BAD COM with a clear background conveys the wrong
COM port is set for RF. To view and adjust the COM ports, select the Settings tab. For additional information, refer to "
Start, Pause, Stop
All ORION endpoints are programmed at the factory to begin sending meter readings as soon as the register
senses flow
through the meter. As a result, you can install ORION endpoints on meters without having to manually start the endpoint.
When water usage is registered on the meter, the endpoint sends a signal every four seconds.
To start an endpoint before installing the meter, use the Start function. Align the optical port and the LED and tap Start.
To pause the radio signal temporarily, use the Pause function.
To stop the endpoint from sending a signal until the Start function is used to turn the endpoint on again, use the Stop
function.