Visonic Inc. MDT122 Manual De Usuario

Descargar
Página de 4
DE2295U 
 
2. SPECIFICATIONS
2. SPECIFICATIONS
2. SPECIFICATIONS
2. SPECIFICATIONS
    
Transmission Type: Radio Frequency (RF) 
RF frequency (MHz): 433.92 
Transmitter’s ID Code: 28-bit ID, Code Secure
TM 
Modulation type: pulse width modulation 
Overall Message Length: 66 bit 
Alarm Messages: Tilt activated, pull-cord disconnected, Panic 
alarm, each with separate ID 
Power Source: 3.6 V, Lithium battery, size 1/2 AA / 1.2 Ah, 
(Tadiran TL-2150 or equivalent.)  
Current Consumption: 15
µ
A standby, 10mA (operation)  
Battery Life Expectancy: Up to 3 years (with regular use) 
Battery Supervision: Battery test every hour  
Operating temperature: 0
°
C to 49
°
C (32
°
F to 120
°
F) 
Dimensions (H x W x D): 120 x 52 x 36 mm (4-3/4 x 2-1/16 x 1-5/16 in.)  
  With Holster-3: 140 x 77 x 50 mm (5-7/16 x 3-1/16 x 1-15/16 in.) 
Housing: 3mm ABS plastic box, weather proof 
Weight: 
Man-down -138 g (4.9 Oz.), Holster-3  - 30 g (1.05 Oz.)  
Color: Body - dark gray, buttons - brown, pull cord - black 
Compliance with Std.:
 FCC Part 15 
Accessories:  Light weight water-resistant carry pouch Holster-3. 
    Metal 
belt 
clip. 
    Pull-cord 
with 
pin 
and 
cloth 
clip. 
 
 
3. FUNCTIONAL DESCRIPTION
3. FUNCTIONAL DESCRIPTION
3. FUNCTIONAL DESCRIPTION
3. FUNCTIONAL DESCRIPTION    
3.1 Visual and Audible Warning Timing 
A built-in tilt sensor activates the unit when the unit is tilted down 
by more than 60
°
 (see figure 3). When the unit is activated, it 
enters a pre-alarm state for 30 seconds. This period enables the 
user to return the transmitter to the normal (vertical) position, to 
prevent an unintentional alarm transmission.  
During this period an audible warning is sounded by the buzzer 
and a visual warning is indicated (by the internal LED). The 
buzzer’s sound can be disabled by using an internal buzzer’s 
switch (see table 1). Figure 4 presents the timing diagram.  
Prealarm time:
15 short beeps
+ 1 long beep
Buzzer
sound
0
30
t (sec.)
MDT-122 is returned
to normal position
before 30 sec.
0
30
MDT-122 is returned to
normal position after 30 sec.
ON
OFF
Part of
prealarm time
Transmission
and LED
0
30
t (sec.)
Alarm
Alarm
restore
ON
OFF
 
Figure 4 - MDT-122  Functional Timing Diagram 
3.2 Low Battery Voltage Indication  
The battery is automatically tested every hour, under load 
condition. If the battery voltage is low, “low battery” message is 
sent every transmission. 
 In addition, when the battery voltage is low, the LED blinks while 
pressing the left or right push-button switch.  
3.3 External Buttons Functions
 (see fig. 2)
  
A.  Left or Right push-buttons 
When left and right push-buttons are pressed, panic alarm is 
transmitted. 
 
B.  Tilt ON-OFF Slide Switch 
By using this switch, the user can disable the tilt sensor 
function (this is necessary when a guard goes off duty or 
performs such activities that can activate the transmitter and 
create a false alarm). When the unit is delivered from the 
factory, the switch is in OFF position. 
C.  Temp Tilt Off Push-Button Switch 
The push-button is located at the top of the unit. It is used for 
temporary disabling (5 minutes) of the tilt sensor function, 
when it is desired. To re-enable tilt function before the 5 
minutes delay expires, the tilt ON-OFF slide switch should be 
switched to OFF position and then to ON again. 
3.4 Pull-Cord Function 
(see par. 1C)
 
3.5 Internal DIP Switches Functions 
Table 1 - Internal DIP Switches Functions 
Switch Description  Default 
1 Buzzer 
ON/OFF 
ON 
Pull-cord option  
ON 
3 (not 
used) 
OFF 
4 (not 
used) 
OFF 
(For future use) 
Tilt alarm delay ON/OFF (*) 
ON 
*    Tilt Alarm Delay Enable/Disable 
30 second pre-alarm delay enabled/disabled. 
If the “tilt alarm delay” DIP switch is set to OFF position (no 
delay) the tilt pre-alarm DIP switch position is disregarded. 
3.6 Buzzer Functions 
The internal buzzer sounds, as shown in figure 4 and in the 
following situations: 
A.  When someone is tampering / stops tampering with the unit.  
B.  Whenever the internal DIP switch setting is changed.