This list of terms is arranged in alphabetical order. 
Any term indicated by cursive (italic) letters within 
the explanatory text can be looked up separately. 
Abort Period: When an alarm is initiated, the 
internal sounder is activated first for a limited period 
of time which is the abort period set by the installer. If 
you cause an alarm accidentally, you can disarm the 
system within the abort period before the real sirens 
start and before the alarm is reported to the remote 
responders. 
Alarm: There are 2 kinds of alarm: 
Loud alarm - both internal and external sirens blare 
out constantly and the control panel reports the event 
by telephone. 
Silent alarm - the sirens remain silent, but the control 
panel reports the event by telephone. 
A state of alarm is caused by: 
• 
Motion detected by a motion detector  
• 
Change of state detected by a magnetic contact 
detector
 - a closed window or door is opened 
• 
Detection of smoke by a smoke detector 
• 
Tampering with any one of the detectors 
• 
Pressing the two emergency buttons simultaneously 
(panic) 
Arming:  Arming the alarm system is an action that 
prepares it to sound an alarm if a zone is “violated” 
by motion or by opening a door or window, as the 
case may be. The control panel may be armed in 
various modes (see AWAY,  HOME, INSTANT and 
LATCHKEY). 
AWAY: This type of arming is used when the 
protected site is vacated entirely. All zones, interior 
and perimeter alike, are protected.  
Chime Zones: Allow you to keep track of activity in 
the protected area while the alarm system is in the 
disarmed state. Whenever a chime zone is "opened", 
the buzzer beeps twice. The buzzer doesn't beep, 
however, upon closing the zone (return to normal). 
Residences can use this feature to annunciate 
visitors or look after children. Businesses can use it 
to signal when customers enter the premises or 
when personnel enter restricted areas.  
Note:  Your installer will never designate a 24-hour 
zone or a fire zone as a chime zone, because both 
zone types actuate an alarm if disturbed while the 
system is in the disarmed state. 
Although one zone or more are designated as chime 
zones, you can still enable or disable the chime 
function. 
Control Panel: The control panel  is a cabinet that 
incorporates the electronic circuitry and 
microprocessor that control the alarm system. It 
collects information from various sensors, processes 
it and responds in various ways. It also includes the 
user-interface - control keys, numerical keypad, 
display, sounder and loudspeaker. 
Disarming:  The opposite of arming - an action that 
restores the control panel to the normal standby 
state. In this state, only fire and  24-hour zones will 
sound an alarm if violated, but a “panic alarm” may 
also be initiated. 
Disturbed Zone: A zone in a state of alarm (this 
may be caused by an open window or door or by 
motion in the field of view of a motion detector). A 
disturbed zone is considered “not secured”. 
Forced Arming: When any one of the system zones 
is  disturbed (open), the alarm system cannot be 
armed. One way to solve this problem is to find and 
eliminate the cause for zone disturbance (closing 
doors and windows). Another way to deal with this is 
to impose forced arming - automatic de-activation of 
zones that are still disturbed upon termination of the 
exit delay. Bypassed zones will not be protected 
throughout the arming period. Even if restored to 
normal (closed), bypassed zones will remain 
unprotected until the system is disarmed.  
Permission to “force arm” is given or denied by the 
installer while programming the system. 
HOME: This type of arming is used when people are 
present within the protected site. A classic example 
is night-time at home, when the family is about to 
retire to bed. With HOME arming, perimeter zones 
are protected but interior zones are not. 
Consequently, motion within interior zones will be 
ignored by the control panel, but disturbance of a 
perimeter zone will cause an alarm. 
Instant: You can arm the system AWAY-INSTANT 
or HOME-INSTANT, thereby canceling the entry 
delay for all delay zones for the duration of one 
arming period.  
For example, you may arm the control panel in the 
HOME-INSTANT mode and remain within the 
protected area. Only perimeter protection is active, 
and if you do not expect somebody to drop in while 
the system is armed, alarm upon entry via the main 
door is an advantage.  
To disarm the system without causing an alarm, use 
your control keypad (which is normally accessible 
without disturbing a perimeter zone) or use a keyfob 
transmitter.