Codan Radio Communications AMP-2-450 Manual De Usuario
UHF AMP-2 30 W Power Amplifier Instruction Manual
IM71-AMP2450-30
3
INSTALLATION AND
SITE OPERATION
GENERAL
The UHF AMP-2 RF power amplifier module is
approved for operation with the MT 3 or
MT 4 exciter. Complete MT 3 subrack systems
shipped directly from the factory are normally
set to the appropriate options and output power
calibration as requested by the customer. These
units require no recalibration.
For UHF AMP-2 RF power amplifiers shipped
separately from the MT 3 subracks, install as
outlined:
1
Confirm exciter and power amplifier are aligned
for the same frequency. (See Alignment Procedure).
2
Remove the blank cover plates or TX-RX pair
in the “B” System subrack slot.
3
Install the UHF AMP-2 in slot 39 (visible via the
marker hole on the upper left UHF AMP-2 front panel).
NOTE: If the unit is being adjusted with the
extender card, a voltage drop of
+1.0 to +1.5 Vdc will occur when the
power amplifier is transmitting. This
voltage drop must be compensated
to permit a valid power output
measurement.
4
Connect the output of the exciter to the input
of the UHF AMP-2 power amplifier with the cable
provided.
5
Connect the antenna system and key the
transmitter. The LED indicators are defined as follows: