Honeywell BOTAC01 Manual De Usuario

Descargar
Página de 32
Honeywell IdentIPoint Intelligent Smartcard Readers 
ASSEMBLY, MOUNTING AND INSTALLATION 
 
Notes:  
 
The reader and IOM can be mounted either 
on a drywall or on a concrete wall using 
conduits and a gang-box.  
 
The drywall and gang-boxes shown here 
are just representations of the actual 
hardware. During installation, use the 
hardware as per the required dimensions 
and availability.  
 
Reader 
Drywall Mounting 
 
1.  Fig.1 and Fig.2 show the parts of the 
IdentIPoint reader. Use the back-plate of 
the reader to mark out the position of the 
reader on the drywall. Mark the positions of 
the mounting screws and the opening for 
routing the cables.  
2.  Cut the cable opening on the drywall using 
suitable tools and punch an adequate 
number of holes for the mounting screws. It 
is advisable to use at least four screws for 
fixing the reader. Use the wall anchors for 
additional holding strength. See Fig.3. 
3.  Hold the back-plate in position on the 
drywall. Align the mounting screws with 
their holes and fasten the back-plate 
securely on the drywall using the screws. 
See Fig.3
4.  Route the field wires including the Ethernet 
cable (if required) from behind the drywall 
through the cable opening and bring them 
to the front of the mounting surface. Clip 
the square ferrite clip on the reader’s 
Ethernet pigtail. See Fig.6. Connect the 
field wiring to the correct Molex pigtails. 
See Fig.5. For reader connection details 
see Fig.10. Plug the Molex terminal(s) in 
ports J9 and J10 at the back of the reader. 
See Fig.6. Clip (with two turns wrapped) 
the round ferrite clip on the field Ethernet 
cable. See Fig.5. Plug the RJ45 connector 
of the field Ethernet cable into the Ethernet 
port of the reader at the end of the pigtail. 
See Fig.6. Drop the excess lengths of 
Molex and Ethernet wires behind the 
drywall. Set the S1 DIP switch if the reader 
is to be connected to an IOM via RS485. 
See Fig.10 and appendix for more details. 
5.  Once all the connections and settings are 
done, hold the reader against the back-
plate, aligning the mounting slots at the 
back of the reader with their corresponding 
catches on the back-plate and push it 
downwards until it hooks into place firmly. 
See Fig.7 and Fig.8.  
6.  Use the Allen wrench to tighten the tamper-
resistant screw at the bottom of the reader. 
See Fig.9
 
Gang-box (concrete wall) Mounting 
 
1.  Fig.1 and Fig.2 show the parts of the 
IdentIPoint reader. Ensure that the correct 
sized gang-box is securely embedded in 
the concrete wall. The holes provided in the 
gang-box for the screws should align 
properly with at least two of the holes 
provided in the reader back-plate for the 
screws. 
2.  Hold the back-plate in position over the 
gang-box. Align the mounting screws with 
their holes and fasten the back-plate 
securely on the gang-box using the screws. 
See Fig.4
 
95-7771