GatesAir Inc. UAXFLID Manual De Usuario

Descargar
Página de 46
10/6/10
888-2721-001
3-3
 
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation & Maintenance 
Maxiva UAX Transmitter Indoor System
User Manual
3.2.1
Control Buttons overview:
TRANSMITTER "ON" and "OFF" (the main transmitter on/off buttons, also used as 
a reset button for latching faults)
POWER "Raise" and "Lower" (to raise or lower transmitter output power)
POWER CONTROL "Auto" and "Man" (for automatic or manual output power con-
trol) to raise or lower the transmitter power, press Raise or Lower to adjust output 
power. Once the output power has been set to the desired level, that level will be 
automatically maintained if the power control is set to Auto.
DRIVE "A" and "B" (To choose Drive Chain A or Drive Chain B) 
DRIVE CONTROL "Auto" and "Man" (In "Manual" mode, operator can select Drive 
Chain A or B. In "Auto" mode, the TCU will automatically switch drive chains if a 
fault occurs in the active drive chain.
REMOTE "Enable" and "Disable" (To block all remote control operations of the 
transmitter). By pressing the "Disable" button, prevents a remote control operator 
from performing any transmitter function while a local operator/engineer is perform-
ing tests or maintenance on the transmitter. 
NOTE:
Be sure to press the "Enable" button before leaving the transmitter facility. 
When leaving the enclosure facility check to make sure the control buttons are lit as 
follows:
POWER CONTROL: Auto
DRIVE: A
DRIVE CONTROL: Auto
REMOTE: Enable
TRANSMITTER: ON
See Figure 3-3 which shows the front of the router. The Console Command Port on the 
front of the router allows the server to set/program the parameters of the system. Also 
note the power switch is also located on the front of the router.