4.7  SYSTEM MENU 
 
The System Menu allows you to set system features as described in the table below. 
Option 
Parameter 
Description 
System Management 
 
Indicates system information. 
If you move the cursor to this option and press Enter
the relevant setting submenu appears on the screen. 
System Part # 
Indicates the product name of N22A. 
System Serial # 
Indicates the serial number of N22A (not used now). 
BIOS Revision 
Indicates the BIOS revision of N22A. 
 
EC FW Revision 
(View only) 
Indicates the EC-FW revision of N22A. 
Temperature Sensor 
Disabled 
Enabled 
Specify the temperature monitoring feature. 
Set to [Disabled] to disable the temperature monitoring 
feature at system booting. 
Set to [Enabled] to enable the temperature monitoring 
feature at system booting. 
Upper Limit [°C] 
75 
Wide Range 
Temperature Support:
80 
Indicates the upper limit of the monitoring 
temperature. 
Lower Limit [°C] 

Wide Range 
Temperature Support:
-25 
Indicates the lower limit of the monitoring 
temperature. 
Voltage Sensor 
Disabled 
Enabled 
Specify the voltage monitoring feature. 
Set to [Disabled] to disable the voltage monitoring 
feature at system booting. 
Set to [Enabled] to enable the voltage monitoring 
feature at system booting. 
POST Errors 
Disabled 
Enabled 
Specify the operation when an error is found during 
POST. 
Set to [Disabled] to have the system continue booting 
if an error is found by the POST. 
Set to [Enabled] to suspend booting if an error is found 
by the POST and indicate the error content. 
HDD Thermal Sensor            *1 
Disabled 
Enabled 
Specify the HDD temperature monitoring feature. 
Set to [Disabled] to disable the HDD temperature 
monitoring feature at system booting. 
Set to [Enabled] to enable the HDD temperature 
monitoring feature at system booting. 
Illumination sensor 
Disabled 
Enabled 
Set the illuminance sensor.   
If “Disabled” is selected, the illuminance sensor is 
disabled.   
If “enabled” is selected, the illuminance sensor is 
enabled. 
LCD Mode 
Normal 
Enhanced 
Change the LCD brightness level. 
If “Normal” is set, the brightness is changed in the 
range from the lowest to level 13.   
If “Enhanced” is set, the brightness is changed in the 
range from the lowest to level 16.   
Self-Diagnostic Program 
 
 
*Shaded value: Factory-set 
*1: For wide temperature range HDD, “HDD Temperature Sensor” is not displayed. 
 
 
 
 
 
 
 
 
 
 
 
Operations when temperature sensor is set to 
“Use” 
Monitor system temperature (internal temperature sensor) at power on (BIOS startup), 
where an error message will appear, after BIOS startup is completed, if the temperature 
is outside the range between upper and lower limits of the setting values. 
The temperature sensor has a margin of error.    In case of operating at temperatures 
close to the lower limit of monitoring temperature, adjust the setting value if an error 
message appears after BIOS startup is completed. 
Do not change 
“Upper Limit of Monitoring Temperature” to a greater value since the main 
unit internal temperature will rise after power is turned on. 
This operation is performed only on startup, and will not be performed after the operating 
system starts.