1.1.3  Environmental Specification (Main Unit) 
 
Item 
Condition 
 
Installation of standard hard disk drive 
and battery 
Installation of silicon disk drive and 
standard battery 
Installation of silicon disk drive and 
stamina standard battery 
Installation of hard disk 
drive and battery of wide 
temperature range 
Operating 
5 to 45 ºC 
(Note 2)
 
-20 to 50ºC 
(Note 2)
 
Storage 
-40 to 70ºC 
Temperature 
Evaluation standard 
IEC 68-2-1,2,14 / MIL-STD-810F, Method 501.4, 502.4 
Operating 
5 to 95% RH (without condensation) 
Storage 
5 to 95% RH (without condensation) 
Humidity 
Evaluation standard 
IEC 68-2-30 / MIL-STD-810F, Method 507.4 
Operating 
15,000 ft (4,572m) 
Storage 
40,000 ft (12,190m) 
Change rate 
2,000 ft/min (609.6 m/min) 
Altitude 
Evaluation standard 
IEC 68-2-13 / MIL-STD-810F, Method 500.4 
Operating 
147 m/s
2
, 11 ms, half sinusoidal wave 
Storage 
490 m/s
2
, 11 ms, half sinusoidal wave 
Shock 
resistance 
(Note 1)
 
Evaluation standard 
IEC 68-2-27 / MIL-STD-810F, Method 516.5 
Operating 
[Sinusoidal wave] 0.075 mm (0-P) in frequency range 10 to 55 Hz 
9.8 m/s
2
 (0-P) in frequency range 55 to 500 Hz 
Storage 
[Sinusoidal wave] 0.15 mm (0-P) in frequency range 10 to 55 Hz 
19.6 m/s
2
 (0-P) in frequency range 55 to 500 Hz 
[Random wave] 0.04G2/Hz in frequency range 20 to 1000 Hz 
-6 dB/Octave in frequency range 1000 to 2000 Hz 
Operating 
Sinusoidal wave: IEC68-2-6 
Vibration 
resistance 
(Note 1)
 
Evaluation 
standard 
Storage 
Sinusoidal wave: IEC68-2-6 
Random wave: MIL-STD-810F, Method 514.5 Category 24 FIGURE 
514.5C-17 
Operating 
IP54 
Storage 
IP54 
Dust proof 
and drip 
proof 
Evaluation standard 
IEC 529 / MIL-STD-810F 
 
IEC: 
Abbreviation for International Electrotechnical Commission. 
MIL: 
Abbreviation for Military Specifications and Standards. 
 
Note 1:  The vibration resistance of N22A does not assure that it has sufficient strength against resonance 
generated when the frequency of added vibration is close to the natural frequency of N22A. 
 
Note 2:  Use the product with an ambient temperature of from 5ºC to 40ºC in tablet mode or while the battery is 
being charged. 
 
*  The specification does not assure that N22A can operate continuously under the described environmental 
conditions in which N22A is installed. 
In addition, if N22A is equipped with one or more NEC or commercial options, the most severe environmental 
condition among those for N22A and the options is applied. Installation environment conditions for external 
optional devices are different that those for the main unit, see the document that comes with each device for 
detailed conditions. 
When N22A is stored at high/low temperatures, the clock built in N22A may be shifted. Set the clock before 
N22A is used again.